FA: TxUNDER
CRC15-8
RxEOP
RxOVF
TxEOP
Name
Name
RXFF
RxFE
TXFL
GA
Table 148 - HDLC Interrupt Status Register
Table 149 - Receive CRC MSB Register
The MSB byte of the CRC received from the transmitter. These bits
are as the transmitter sent them; that is, most significant bit first and
inverted. This register is updated at the end of each received packet
and therefore should be read when end of packet is detected.
Go Ahead. Indicates a go-ahead pattern was detected by the HDLC
receiver. This bit is reset after a read.
End Of Packet Detected. This bit is set when an end of packet
(EOP) byte was written into the RX FIFO by the HDLC receiver. This
can be in the form of a flag, an abort sequence or as an invalid
packet. This bit is reset after a read.
Transmit End Of Packet. This bit is set when the transmitter has
finished sending the closing flag of a packet or after a packet has
been aborted. This bit is reset after read.
End Of Packet Read. This bit is set when the byte about to be read
from the RX FIFO is the last byte of the packet. It is also set if the Rx
FIFO is read and there is no data in it. This bit is reset after a read.
TX FIFO Low. This bit is set when the Tx FIFO is emptied below the
selected low threshold level. This bit is reset after a read.
Frame Abort/TX FIFO Underrun.When Intsel bit of Control Register
2 is low, this bit (FA) is set when a frame abort is received during pack-
et reception. It must be received after a minimum number of bits have
been received (26) otherwise it is ignored.
When INTSEL bit of Control Register 2 is high, this bit is set for a TX
FIFO underrun indication. If high it Indicates that a read by the
transmitter was attempted on an empty Tx FIFO.
This bit is reset after a read.
RX FIFO Full. This bit is set when the Rx FIFO is filled above the
selected full threshold level. This bit is reset after a read.
RX FIFO Overflow. Indicates that the 128 byte RX FIFO overflowed
(i.e. an attempt to write to a 128 byte full RX FIFO). The HDLC will
always disable the receiver once the receive overflow has been
detected. The receiver will be re-enabled upon detection of the next
flag, but will overflow again unless the RX FIFO is read. This bit is
reset after a read.
(Page B & C, Address 17H)
(Page B & C, Address 18H)