3.9.3. Syndrome Detector
If there is a correctable error in the read data word, the correction is performed
according to the following procedure:
In case of Syndrome(7:0)
MATRA MHS
Rev. D (10 Apr. 97)
when "00111000" => Corrected Data = Data xor "000000000000000000000000000000001"
when "01000101" => Corrected Data = Data xor "000000000000000000000000000000010"
when "01010100" => Corrected Data = Data xor "000000000000000000000000000000100"
when "00010110" => Corrected Data = Data xor "000000000000000000000000000001000"
when "00011111" => Corrected Data = Data xor "000000000000000000000000000010000"
when "00100101" => Corrected Data = Data xor "000000000000000000000000000100000"
when "00100110" => Corrected Data = Data xor "000000000000000000000000001000000"
when "01001010" => Corrected Data = Data xor "000000000000000000000000010000000"
when "00101111" => Corrected Data = Data xor "000000000000000000000000100000000"
when "00111011" => Corrected Data = Data xor "000000000000000000000001000000000"
when "00111101" => Corrected Data = Data xor "000000000000000000000010000000000"
when "01100001" => Corrected Data = Data xor "000000000000000000000100000000000"
when "00011010" => Corrected Data = Data xor "000000000000000000001000000000000"
when "00101010" => Corrected Data = Data xor "000000000000000000010000000000000"
when "00101100" => Corrected Data = Data xor "000000000000000000100000000000000"
when "01001111" => Corrected Data = Data xor "000000000000000001000000000000000"
when "01000110" => Corrected Data = Data xor "000000000000000010000000000000000"
when "01010010" => Corrected Data = Data xor "000000000000000100000000000000000"
when "01100100" => Corrected Data = Data xor "000000000000001000000000000000000"
when "01011101" => Corrected Data = Data xor "000000000000010000000000000000000"
when "00100011" => Corrected Data = Data xor "000000000000100000000000000000000"
when "00110001" => Corrected Data = Data xor "000000000001000000000000000000000"
when "01001100" => Corrected Data = Data xor "000000000010000000000000000000000"
when "01101000" => Corrected Data = Data xor "000000000100000000000000000000000"
when "00010011" => Corrected Data = Data xor "000000001000000000000000000000000"
when "00110010" => Corrected Data = Data xor "000000010000000000000000000000000"
when "00110100" => Corrected Data = Data xor "000000100000000000000000000000000"
when "01011000" => Corrected Data = Data xor "000001000000000000000000000000000"
when "01000011" => Corrected Data = Data xor "000010000000000000000000000000000"
when "01010001" => Corrected Data = Data xor "000100000000000000000000000000000"
when "01011011" => Corrected Data = Data xor "001000000000000000000000000000000"
when "01101101" => Corrected Data = Data xor "010000000000000000000000000000000"
when "00000000" => Corrected Data = Data xor "100000000000000000000000000000000"
when "10000000" => Corrected Data = Data xor "000000000000000000000000000000000" (no error)