h8s-2649 Renesas Electronics Corporation., h8s-2649 Datasheet - Page 517

no-image

h8s-2649

Manufacturer Part Number
h8s-2649
Description
Renesas 16-bit Single-chip Microcomputer H8s Family/h8s/2600 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet
15.3.2
ADCSR controls A/D conversion operations.
Bit
7
6
5
4
Bit Name
ADF
ADIE
ADST
SCAN
A/D Control/Status Register (ADCSR)
Initial
Value
0
0
0
0
R/W
R/(W)
R/W
R/W
R/W
A/D End Flag
A/D Interrupt Enable
Scan Mode
Description
A status flag that indicates the end of A/D conversion.
[Setting conditions]
[Clearing conditions]
A/D conversion end interrupt (ADI) is enabled when this
bit is set to 1.
A/D Start
Clearing this bit to 0 stops A/D conversion, and the A/D
converter enters the wait state.
Setting this bit to 1 starts A/D conversion. In single
mode, this bit is automatically cleared to 0 when
conversion on the specified channel is complete. In
scan mode, conversion continues sequentially on the
specified channels until this bit is cleared to 0 by
software, a reset, or a transition to software standby
mode, hardware standby mode or module stop mode.
Selects the A/D conversion operating mode.
0: Single mode
1: Scan mode
When A/D conversion ends
When A/D conversion ends on all specified
channels
When 0 is written after reading ADF = 1
When the DTC is activated by an ADI interrupt and
ADDR is read
Rev. 2.00 Dec. 05, 2005 Page 479 of 724
Section 15 A/D Converter
REJ09B0200-0200

Related parts for h8s-2649