MC68HC908MR16CFU Freescale Semiconductor, MC68HC908MR16CFU Datasheet - Page 52

no-image

MC68HC908MR16CFU

Manufacturer Part Number
MC68HC908MR16CFU
Description
IC MCU 8MHZ 16K FLASH 64-QFP
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MC68HC908MR16CFU

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM
Number Of I /o
44
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 10x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908MR16CFU
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68HC908MR16CFUE
Manufacturer:
ALTERA
Quantity:
101
Analog-to-Digital Converter (ADC)
3.7.1 ADC Status and Control Register
This section describes the function of the ADC status and control register (ADSCR). Writing ADSCR
aborts the current conversion and initiates a new conversion.
COCO — Conversions Complete Bit
AIEN — ADC Interrupt Enable Bit
ADCO — ADC Continuous Conversion Bit
ADCH[4:0] — ADC Channel Select Bits
52
In non-interrupt mode (AIEN = 0), COCO is a read-only bit that is set at the end of each conversion.
COCO will stay set until cleared by a read of the ADC data register. Reset clears this bit.
In interrupt mode (AIEN = 1), COCO is a read-only bit that is not set at the end of a conversion. It
always reads as a 0.
When this bit is set, an interrupt is generated at the end of an ADC conversion. The interrupt signal is
cleared when the data register is read or the status/control register is written. Reset clears the AIEN bit.
When set, the ADC will convert samples continuously and update the ADR register at the end of each
conversion. Only one conversion is allowed when this bit is cleared. Reset clears the ADCO bit.
ADCH4, ADCH3, ADCH2, ADCH1, and ADCH0 form a 5-bit field which is used to select one of 10 ADC
channels. The ADC channels are detailed in
The ADC subsystem is turned off when the channel select bits are all set to 1. This feature allows for
reduced power consumption for the MCU when the ADC is not used.
1 = Conversion completed (AIEN = 0)
0 = Conversion not completed (AIEN = 0) or CPU interrupt enabled
1 = ADC interrupt enabled
0 = ADC interrupt disabled
1 = Continuous ADC conversion
0 = One ADC conversion
(AIEN = 1)
Address: $0040
The write function of the COCO bit is reserved. When writing to the ADSCR
register, always have a 0 in the COCO bit position.
Take care to prevent switching noise from corrupting the analog signal
when simultaneously using a port pin as both an analog and digital input.
Recovery from the disabled state requires one conversion cycle to stabilize.
Reset:
Read:
Write:
COCO
Figure 3-4. ADC Status and Control Register (ADSCR)
Bit 7
R
R
0
MC68HC908MR32 • MC68HC908MR16 Data Sheet, Rev. 6.1
= Reserved
AIEN
6
0
ADCO
5
0
Table
NOTE
NOTE
NOTE
ADCH4
4
1
3-1.
ADCH3
3
1
ADCH2
2
1
ADCH1
1
1
Freescale Semiconductor
ADCH0
Bit 0
1

Related parts for MC68HC908MR16CFU