Enhanced Serial Communications Interface (ESCI) Module
IDLE — Receiver Idle Bit
OR — Receiver Overrun Bit
210
This clearable, read-only bit is set when 10 or 11 consecutive 1s appear on the receiver input. IDLE
generates an ESCI receiver CPU interrupt request if the ILIE bit in SCC2 is also set. Clear the IDLE
bit by reading SCS1 with IDLE set and then reading the SCDR. After the receiver is enabled, it must
receive a valid character that sets the SCRF bit before an idle condition can set the IDLE bit. Also, after
the IDLE bit has been cleared, a valid character must again set the SCRF bit before an idle condition
can set the IDLE bit. Reset clears the IDLE bit.
This clearable, read-only bit is set when software fails to read the SCDR before the receive shift
register receives the next character. The OR bit generates an ESCI error CPU interrupt request if the
ORIE bit in SCC3 is also set. The data in the shift register is lost, but the data already in the SCDR is
not affected. Clear the OR bit by reading SCS1 with OR set and then reading the SCDR. Reset clears
the OR bit.
Software latency may allow an overrun to occur between reads of SCS1 and SCDR in the flag-clearing
sequence.
caused by a delayed flag-clearing sequence. The delayed read of SCDR does not clear the OR bit
because OR was not set when SCS1 was read. Byte 2 caused the overrun and is lost. The next
flag-clearing sequence reads byte 3 in the SCDR instead of byte 2.
1 = Receiver input idle
0 = Receiver input active (or idle since the IDLE bit was cleared)
1 = Receive shift register full and SCRF = 1
0 = No receiver overrun
Figure 14-14
MC68HC908GZ60 • MC68HC908GZ48 • MC68HC908GZ32 Data Sheet, Rev. 6
BYTE 1
BYTE 1
shows the normal flag-clearing sequence and an example of an overrun
READ SCDR
READ SCS1
SCRF = 1
Figure 14-14. Flag Clearing Sequence
BYTE 1
OR = 0
READ SCDR
READ SCS1
DELAYED FLAG CLEARING SEQUENCE
NORMAL FLAG CLEARING SEQUENCE
BYTE 2
BYTE 2
SCRF = 1
BYTE 1
OR = 0
READ SCDR
READ SCS1
SCRF = 1
BYTE 2
OR = 0
BYTE 3
BYTE 3
READ SCDR
READ SCDR
READ SCS1
READ SCS1
SCRF = 1
SCRF = 1
BYTE 3
BYTE 3
OR = 1
OR = 0
BYTE 4
BYTE 4
Freescale Semiconductor