UPD70F3765GF-GAT-AX Renesas Electronics America, UPD70F3765GF-GAT-AX Datasheet - Page 1053

no-image

UPD70F3765GF-GAT-AX

Manufacturer Part Number
UPD70F3765GF-GAT-AX
Description
MCU 32BIT V850ES/JX3-H 128-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Hr
Datasheet

Specifications of UPD70F3765GF-GAT-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3765GF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-H, V850ES/JH3-H
R01UH0042EJ0400 Rev.4.00
Sep 30, 2010
(2) Processing
The processing of an automatic request in the Default state, Addressed state, and Configured state is described
below.
Remark
(a) CLEAR_FEATURE() request
(b) GET_CONFIGURATION() request
A STALL response is made in the status stage if the CLEAR_FEATURE() request cannot be cleared, if
FEATURE does not exist, or if the target is an interface or an endpoint that does not exist. A STALL response
is also made if the wLength value is other than 0.
• Default state:
• Addressed state: The correct response is made when the CLEAR_FEATURE() request has been received
• Configured state: The correct response is made when the CLEAR_FEATURE() request has been received
When the CLEAR_FEATURE() request has been correctly processed, the corresponding bit of the UF0 CLR
request register (UF0CLR) is set to 1, the EnHALT bit of the UF0 EPn status register L (UF0EnSL) is cleared to
0, and an interrupt is issued (n = 0 to 4, 7). If the CLEAR_FEATURE() request is received when the subject is
an endpoint, the toggle bit (that controls switching between DATA0 and DATA1) of the corresponding endpoint
is always re-set to DATA0.
A STALL response is made in the data stage if any of wValue, wIndex, or wLength is other than the values
shown in Table 21-3.
• Default state:
• Addressed state: The value stored in the UF0CNF register is returned when the GET_CONFIGURATION()
• Configured state: The value stored in the UF0CNF register is returned when the GET_CONFIGURATION()
Default state: State in which an operation is performed with the Default address
Addressed state: State after an address has been allocated
Configured state: State after SET_CONFIGURATION wValue = 1 has been correctly received
The correct response is made when the CLEAR_FEATURE() request has been received
only if the target is a device or a request for Endpoint0; otherwise a STALL response is
made in the status stage.
only if the target is a device or a request for Endpoint0; otherwise a STALL response is
made in the status stage.
only if the target is a device or a request for an endpoint that exists; otherwise a STALL
response is made in the status stage.
The value stored in the UF0 configuration register (UF0CNF) is returned when the
GET_CONFIGURATION() request has been received.
request has been received.
request has been received.
CHAPTER 21 USB FUNCTION CONTROLLER (USBF)
Page 1053 of 1509