AT91SAM7X128 Atmel, AT91SAM7X128 Datasheet - Page 318

no-image

AT91SAM7X128

Manufacturer Part Number
AT91SAM7X128
Description
MCU 32-Bit 91S ARM7TDMI RISC 128KB Flash 1.8V/3.3V 100-Pin LQFP
Manufacturer
Atmel
Datasheet

Specifications of AT91SAM7X128

Package
100LQFP
Device Core
ARM7TDMI
Family Name
91S
Maximum Speed
55 MHz
Ram Size
32 KB
Program Memory Size
128 KB
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Program Memory Type
Flash
Number Of Programmable I/os
62
Interface Type
CAN/Ethernet/SPI/I2S/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7X128-AU
Manufacturer:
ATMEL
Quantity:
1 045
Part Number:
AT91SAM7X128-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-AU-999
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-CU-999
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128B-AU
Manufacturer:
Atmel
Quantity:
1 929
Part Number:
AT91SAM7X128B-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128B-AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Figure 30-13. Timeguard Operations
30.6.3.8
318
Baud Rate
TXEMPTY
US_THR
TXRDY
Clock
Write
TXD
AT91SAM7X512/256/128 Preliminary
Receiver Time-out
Start
Bit
D0
D1
Table 30-7
in relation to the function of the Baud Rate.
Table 30-7.
The Receiver Time-out provides support in handling variable-length frames. This feature detects
an idle condition on the RXD line. When a time-out is detected, the bit TIMEOUT in the Channel
Status Register (US_CSR) rises and can generate an interrupt, thus indicating to the driver an
end of frame.
The time-out delay period (during which the receiver waits for a new character) is programmed
in the TO field of the Receiver Time-out Register (US_RTOR). If the TO field is programmed at
0, the Receiver Time-out is disabled and no time-out is detected. The TIMEOUT bit in US_CSR
remains at 0. Otherwise, the receiver loads a 16-bit counter with the value programmed in TO.
This counter is decremented at each bit period and reloaded each time a new character is
received. If the counter reaches 0, the TIMEOUT bit in the Status Register rises. Then, the user
can either:
D2
• Stop the counter clock until a new character is received. This is performed by writing the
Control Register (US_CR) with the STTTO (Start Time-out) bit at 1. In this case, the idle state
D3
D4
D5
Baud Rate
indicates the maximum length of a timeguard period that the transmitter can handle
115200
Bit/sec
14400
19200
28800
33400
56000
57600
1 200
9 600
D6
Maximum Timeguard Length Depending on Baud Rate
D7
Parity
Bit
Stop
Bit
TG = 4
Start
Bit
D0
Bit time
69.4
52.1
34.7
29.9
17.9
17.4
833
104
8.7
µs
D1
D2
D3
D4
D5
D6
D7
Parity
Bit
Stop
Bit
Timeguard
212.50
26.56
17.71
13.28
8.85
7.63
4.55
4.43
2.21
6120H–ATARM–17-Feb-09
ms
TG = 4

Related parts for AT91SAM7X128