AT91SAM7X128 Atmel, AT91SAM7X128 Datasheet - Page 543

no-image

AT91SAM7X128

Manufacturer Part Number
AT91SAM7X128
Description
MCU 32-Bit 91S ARM7TDMI RISC 128KB Flash 1.8V/3.3V 100-Pin LQFP
Manufacturer
Atmel
Datasheet

Specifications of AT91SAM7X128

Package
100LQFP
Device Core
ARM7TDMI
Family Name
91S
Maximum Speed
55 MHz
Ram Size
32 KB
Program Memory Size
128 KB
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Program Memory Type
Flash
Number Of Programmable I/os
62
Interface Type
CAN/Ethernet/SPI/I2S/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7X128-AU
Manufacturer:
ATMEL
Quantity:
1 045
Part Number:
AT91SAM7X128-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-AU-999
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-CU-999
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128B-AU
Manufacturer:
Atmel
Quantity:
1 929
Part Number:
AT91SAM7X128B-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128B-AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
AT91SAM7X512/256/128 Preliminary
• BOFF: Bus Off Mode
0 = CAN controller is not in Bus Off Mode.
1 = CAN controller is in Bus Off Mode.
This flag is set depending on TEC counter value. A node is bus off when TEC counter is greater or equal to 256 (decimal).
This flag is automatically reset when above condition is not satisfied. Refer to
Section 36.6.4.6 “Error Interrupt Handler” on
page 517
for more information.
• SLEEP: CAN controller in Low power Mode
0 = CAN controller is not in low power mode.
1 = CAN controller is in low power mode.
This flag is automatically reset when Low power mode is disabled
• WAKEUP: CAN controller is not in Low power Mode
0 = CAN controller is in low power mode.
1 = CAN controller is not in low power mode.
When a WAKEUP event occurs, the CAN controller is synchronized with the bus activity. Messages can be transmitted or
received. The CAN controller clock must be available when a WAKEUP event occurs. This flag is automatically reset when
the CAN Controller enters Low Power mode.
• TOVF: Timer Overflow
0 = The timer has not rolled-over FFFFh to 0000h.
1 = The timer rolls-over FFFFh to 0000h.
This flag is automatically cleared by reading CAN_SR register.
• TSTP Timestamp
0 = No bus activity has been detected.
1 = A start of frame or an end of frame has been detected (according to the TEOF field in the CAN_MR register).
This flag is automatically cleared by reading the CAN_SR register.
• CERR: Mailbox CRC Error
0 = No CRC error occurred during a previous transfer.
1 = A CRC error occurred during a previous transfer.
A CRC error has been detected during last reception.
This flag is automatically cleared by reading CAN_SR register.
• SERR: Mailbox Stuffing Error
0 = No stuffing error occurred during a previous transfer.
1 = A stuffing error occurred during a previous transfer.
A form error results from the detection of more than five consecutive bit with the same polarity.
This flag is automatically cleared by reading CAN_SR register.
543
6120H–ATARM–17-Feb-09

Related parts for AT91SAM7X128