Specifications of PEB 4364 T V1.2

Function
Dual Channel Subscriber Line Interface Circuit (DuSLIC)
Interface
IOM-2, PCM
Number Of Circuits
2
Voltage - Supply
3.3 V ~ 5 V
Current - Supply
105mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
36-PDSO
Includes
DTMF Generator and Decoder, Line Echo Cancellation (LEC), Teletax (TTX) Generation, Universal Tone Detection (UTD)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB4364TV1.2XT
SP000007728
LEC-ADAPT
LEC-FREEZE Line Echo Cancellation Adaptation Freeze
CIS-FRM
CIS-V23
Preliminary Data Sheet
Caller ID Sender Mode
CIS-V23 = 0
CIS-V23 = 1
Caller ID Sender Framing
CIS-FRM = 0
CIS-FRM = 1
Line Echo Cancellation Adaptation Start. The LEC-ADAPT bit is only
evaluated if the LEC-EN is changed from 0 to 1.
To initialize the LEC coefficients to 0 requires the LEC-ADAPT bit set
to 0 followed by the LEC-EN bit changed from 0 to 1.
It is not possible to reset the LEC coefficients to 0 while the LEC is
running. The LEC has to be disabled first by setting bit LEC-EN to 0 and
then it is necessary to enable the LEC again (LEC-EN = 1, LEC-ADAPT
= 0). If valid coefficients from a former LEC adaptation are present in
the RAM, it is possible to activate the LEC with this coefficents by
setting bit LEC-ADAPT to 1.
It is also possible to read out adapted coefficients from the LEC for
external storage and to reuse these coefficients as a start up value for
the next connection (see the available Application Notes).
LEC-ADAPT = 0
LEC-ADAPT = 1
LEC-FREEZE = 0 No freezing of coefficients
LEC-FREEZE = 1 Freezing of coefficients
Bell 202 selected
V.23 selected
Low-level framing: all data for CID transmissions must
be written to the CID Buffer including channel seizure
and mark sequence, start and stop bits.
High-level framing: channel seizure and mark sequence
as well as start and stop bits are automatically inserted
by the SLICOFI-2x. Only transmission bytes from the
Data Packet (see
CIS buffer.
Line Echo Cancellation coefficients initialized with
zero.
Line Echo Cancellation coefficients initialized with
old coefficients.
249
Figure
30) have to be written to the
DS3, 2003-07-11
DuSLIC