PEB22554 SIEMENS [Siemens Semiconductor Group], PEB22554 Datasheet - Page 131

no-image

PEB22554

Manufacturer Part Number
PEB22554
Description
ICs for Communications
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
PEB22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
PEB22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
PEB22554HT V1.3
Quantity:
1 078
Part Number:
PEB22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
PEB22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
PEB22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Semiconductor Group
Pulse Count Detection Register (Read/Write)
Value after RESET: 00
PCD
PCD7…PCD0… Pulse Count Detection
Pulse Count Recovery (Read/Write)
Value after RESET: 00
PCR
PCR7…PCR0… Pulse Count Recovery
7
7
PCD7
PCR7
A LOS alarm will be detected if the incoming data stream has no
transitions for a programmable number T consecutive pulse
positions. The number T is programmable via the PCD register and
can be calculated as follows:
T= 16(N+1) ; with 0 =< N =< 255.
The maximum time is: 256 x 16 x 488 ns = 2 ms. Every detected pulse
will reset the internal pulse counter. The counter will be clocked with
the receive clock RCLK.
A LOS alarm will be cleared if a pulse density is detected in the
received bit stream. The number of pulses M which must occur in the
predefined PCD time interval is programmable via the PCR register
and can be calculated as follows:
M = N+1 ; with 0 =< N =< 255.
The time interval starts with the first detected pulse transition. With
every received pulse a counter will be incremented and the actual
counter is compared with the contents of PCR register. If the pulse
number >= the PCR value the LOS alarm will be reset otherwise the
alarm will still be active. In this case the next detected pulse transition
will start a new time interval.
H
H
131
Operational Description E1
0
0
PCD0
PCR0
PEB 22554
(x39)
(x38)
09.98