PEB22554 SIEMENS [Siemens Semiconductor Group], PEB22554 Datasheet - Page 304

no-image

PEB22554

Manufacturer Part Number
PEB22554
Description
ICs for Communications
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
PEB22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
PEB22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
PEB22554HT V1.3
Quantity:
1 078
Part Number:
PEB22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
PEB22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
PEB22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Transmit Control 0 (Read/Write)
Value after RESET: 00
XC0
BRM…
MFBS…
BRFO…
XCO10…XCO8… Transmit Offset
Transmit Control 1 (Read/Write)
Value after RESET: 9C
XC1
XTO7…XTO0… Transmit Offset
Semiconductor Group
7
7
XTO7
BRM
Enable Bit Robbing Marker
A one in this bit will mark the robbed bit positions on the system
highway. RSIGM marks the receive and XSIGM marks the transmit
robbed bits.
Enable pure Multiframe Begin Signals
Only valid if ESF or F72 format is selected.
If set, signals RMFB and XMFB indicate only the multiframe begin.
Additional pulses (every 12 frames) are disabled.
Bit Robbing Force One
Setting this bit forces the robbed bits high transmitted on port RDO.
The received signaling data stream for the signaling controller is not
influenced by this bit.
Initial value loaded into the transmit bit counter at the trigger edge of
SCLKX when the synchronous pulse at port SYPX or XMFS is active
Refer to register XC1.
A write access to this address resets the transmit elastic buffer to its
basic starting position. Therefore, updating the value should only be
done when the QuadFALC is initialized or when the buffer should be
centered. As a consequence a transmit slip may occur.
Initial value loaded into the transmit bit counter at the trigger edge of
SCLKX when the synchronous pulse at port SYPX / XMFS is active
(see figure 55+56).
MFBS
H
H
304
BRFO
XCO10
Operational Description T1 / J1
0
0
XCO8
XTO0
PEB 22554
(x22)
(x23)
09.98

Related parts for PEB22554