PEB22554 SIEMENS [Siemens Semiconductor Group], PEB22554 Datasheet - Page 146

no-image

PEB22554

Manufacturer Part Number
PEB22554
Description
ICs for Communications
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
PEB22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
PEB22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
PEB22554HT V1.3
Quantity:
1 078
Part Number:
PEB22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
PEB22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
PEB22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
XPC2 ...0…
Semiconductor Group
100…RSIG : Receive Signaling Data (Output)
101…DLR : Data Link Bit Receive (Output)
110…FREEZ : Freeze Signaling (Output)
111…RFSP : Receive Frame Synchronous Pulse (Output)
Transmit multifunction Port Configuration
The multifunction ports XP(A-D) are bidirectional. After Reset these
ports are configured as inputs. With the selection of the pin function
the In/Output configuration is also achieved. Each of the four different
input functions ( SYPX, XMFS, XSIG, TCLK ) may only be selected
once. No input function should be selected twice or more. SYPX and
XMFS should not be selected in parallel. Register PC1 configures
port XPA,while PC2 --> port XPB, PC3 --> port XPC and PC4 --> port
XPD.
000…SYPX: Synchronous Pulse Transmit (Input)
001…XMFS : Transmit Multiframe Synchronization (Input)
010…XSIG : Transmit Signaling Data (Input)
The received CAS multiframe is transmitted on this pin. Time-
slots on RSIG correlates directly to the time-slot assignment on
RDO. In system interface multiplex mode all four received
signaling data streams are merged into a single rail data stream
byte or bit interleaved on RSIG1.
Marks the SA8-4 bits within the data stream on RDO.
The freeze signaling status is active high by detecting a Loss of
Signal alarm, or a Loss of CAS Frame Alignment or a receive
slip (pos. or neg.). It will hold high for at least one complete
multiframe after the alarm disappears. Setting SIC2.FFS
enforces a high on pin FREEZ.
Marks the frame begin in the receivers synchrounous state.
This marker is active low for 488 ns with a frequency of 8 kHz.
Together with register XC1/0 SYPX defines the frame begin on
the transmit system interface ports XDI and XSIG.
Together with register XC1/0 XMFS defines the frame and
multiframe begin on the transmit system interface ports XDI
and XSIG. Depending on PC5.CXMFS the signal on XMFS is
active high or low.
Input for transmit signaling data received from the signaling
highway. In system interface multiplex mode latching of the
data stream containing the 4 signaling multiframes is done byte
or bit interleaved on port XDI1. Optionally sampling of XSIG
data is controlled by the active high XSIGM marker.