EP2AGX95EF29C4N Altera, EP2AGX95EF29C4N Datasheet - Page 292

no-image

EP2AGX95EF29C4N

Manufacturer Part Number
EP2AGX95EF29C4N
Description
IC ARRIA II GX FPGA 95K 780FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX95EF29C4N

Number Of Logic Elements/cells
89178
Number Of Labs/clbs
3747
Total Ram Bits
6679
Number Of I /o
372
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
93674
# I/os (max)
372
Frequency (max)
500MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
93674
Ram Bits
7025459.2
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX95EF29C4N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX95EF29C4N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX95EF29C4N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
10–8
Arria II GX Device Handbook, Volume 1
You can set a lower clock frequency by specifying a division factor in the Quartus II
software (refer to
where n is between 1 and 8. The divisor ranges from 2 through 256 (refer to
Equation
Equation 10–1.
The error message register is updated whenever an error occurs. If the error location
and message are not shifted out before the next error location is found, the previous
error location and message is overwritten by the new information. To avoid this, you
must shift these bits out within one frame CRC verification. The minimum interval
time between each update for the error message register depends on the device and
the error detection clock frequency. However, slowing down the error detection clock
frequency slows down the error recovery time for the SEU event.
Table 10–7
error message register for Arria II GX devices.
Table 10–7. Minimum Update Interval for Error Message Register
1
10–1).
The error detection frequency reflects the frequency of the error detection
process for a frame because the CRC calculation in Arria II GX devices is
done on a per-frame basis.
lists the estimated minimum interval time between each update for the
EP2AGX125
EP2AGX190
EP2AGX260
EP2AGX45
EP2AGX65
EP2AGX95
“Software Support” on page
Device
error detection frequency
10–9). The divisor is a power of two (2),
=
Chapter 10: SEU Mitigation in Arria II GX Devices
100MHz
------------------- -
2
n
Timing Interval (s)
© July 2010 Altera Corporation
11.04
11.04
14.88
14.88
19.64
19.64
Error Detection Timing

Related parts for EP2AGX95EF29C4N