DS72011RB120FPV Renesas Electronics America, DS72011RB120FPV Datasheet - Page 892

IC SH7201 MPU ROMLESS 176LQFP

DS72011RB120FPV

Manufacturer Part Number
DS72011RB120FPV
Description
IC SH7201 MPU ROMLESS 176LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7200r
Datasheet

Specifications of DS72011RB120FPV

Core Size
32-Bit
Core Processor
SH-2A
Speed
120MHz
Connectivity
CAN, EBI/EMI, FIFO, I²C, SCI, Serial Sound
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 70°C
Package / Case
176-LQFP
No. Of I/o's
109
Ram Memory Size
32KB
Cpu Speed
120MHz
Digital Ic Case Style
LQFP
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-20°C To +70°C
Embedded Interface Type
I2C, SSI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
R0K572011S000BE - KIT STARTER FOR SH7201HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)
Eeprom Size
-
Program Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS72011RB120FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 19 Controller Area Network (RCAN-ET)
• Normal Mode
• Listen-Only Mode:
• Self Test Mode 1
• Self Test Mode 2
• Write Error Counter
• Error Passive mode
Note: the REC will not be modified by implementing this Mode. However, once running in
When message error occurs, IRR13 is set in all test modes.
Page 864 of 1190
RCAN-ET operates in the normal mode.
ISO-11898 requires this mode for baud rate detection. The Error Counters are cleared and
disabled so that the TEC/REC does not increase the values, and the CTx Output is disabled so
that RCAN-ET does not generate error frames or acknowledgment bits. IRR13 is set when a
message error occurs.
RCAN-ET generates its own Acknowledge bit, and can store its own messages into a reception
mailbox (if required). The CRx/CTx pins must be connected to the CAN bus.
RCAN-ET generates its own Acknowledge bit, and can store its own messages into a reception
mailbox (if required). The CRx/CTx pins do not need to be connected to the CAN bus or any
external devices, as the internal CTx is looped back to the internal CRx. CTx pin outputs only
recessive bits and CRx pin is disabled.
TEC/REC can be written in this mode. RCAN-ET can be forced to become an Error Passive
mode by writing a value greater than 127 into the Error Counters. The value written into TEC
is used to write into REC, so only the same value can be set to these registers. Similarly,
RCAN-ET can be forced to become an Error Warning by writing a value greater than 95 into
them.
RCAN-ET needs to be in Halt Mode when writing into TEC/REC (MCR1 must be "1" when
writing to the Error Counter). Furthermore this test mode needs to be exited prior to leaving
Halt mode.Error Passive Mode: RCAN-ET can be forced to enter Error Passive mode.
Error Passive Mode, the REC will increase normally should errors be received. In this
Mode, RCAN-ET will enter BusOff if TEC reaches 256 (Dec). However when this mode
is used RCAN-ET will not be able to become Error Active. Consequently, at the end of the
Bus Off recovery sequence, RCAN-ET will move to Error Passive and not to Error Active