DS72011RB120FPV Renesas Electronics America, DS72011RB120FPV Datasheet - Page 936

IC SH7201 MPU ROMLESS 176LQFP

DS72011RB120FPV

Manufacturer Part Number
DS72011RB120FPV
Description
IC SH7201 MPU ROMLESS 176LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7200r
Datasheet

Specifications of DS72011RB120FPV

Core Size
32-Bit
Core Processor
SH-2A
Speed
120MHz
Connectivity
CAN, EBI/EMI, FIFO, I²C, SCI, Serial Sound
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 70°C
Package / Case
176-LQFP
No. Of I/o's
109
Ram Memory Size
32KB
Cpu Speed
120MHz
Digital Ic Case Style
LQFP
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-20°C To +70°C
Embedded Interface Type
I2C, SSI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
R0K572011S000BE - KIT STARTER FOR SH7201HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)
Eeprom Size
-
Program Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS72011RB120FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 21 D/A Converter (DAC)
21.5
21.5.1
Operation of the D/A converter can be disabled or enabled using the standby control register. The
initial setting is for operation of the D/A converter to be halted. Register access is enabled by
canceling module standby mode. For details, see section 25, Power-Down Modes.
21.5.2
When this LSI enters software standby mode with D/A conversion enabled, the D/A outputs are
retained, and the analog power supply current is equal to as during D/A conversion. If the analog
power supply current needs to be reduced in software standby mode, clear the DAOE0, DAOE1,
and DAE bits to 0 to disable the D/A outputs.
21.5.3
When this LSI enters deep standby mode with D/A conversion enabled, the D/A conversion is
stopped and thus the D/A outputs are also stopped. Before entering deep standby mode, clear the
DAOE0, DAOE1, and DAE bits to 0 to disable the D/A outputs.
21.5.4
The reliability of this LSI may be adversely affected if the following voltage ranges are exceeded.
1. AVcc and AVss input voltages
2. Setting range of AVref input voltage
Page 908 of 1190
Input voltages AVcc and AVss should be PVcc − 0.3 V ≤ AVcc ≤ PVcc and AVss = PVss. Do
not leave the AVcc and AVss pins open when the A/D converter or D/A converter is not in use
and in software standby mode. When not in use, connect AVcc to the power supply (PVcc)
and AVss to the ground (PVss).
Set the reference voltage range of the AVref pin as 3.0 V ≤ AVref ≤ AVcc.
Usage Notes
Module Standby Mode Setting
D/A Output Hold Function in Software Standby Mode
D/A Conversion and D/A Output in Deep Standby Mode
Setting Analog Input Voltage
R01UH0026EJ0300 Rev. 3.00