R88M-WP10030S-WS1 Omron, R88M-WP10030S-WS1 Datasheet - Page 363

no-image

R88M-WP10030S-WS1

Manufacturer Part Number
R88M-WP10030S-WS1
Description
SERVO MOTOR 100W 100V
Manufacturer
Omron
Datasheet

Specifications of R88M-WP10030S-WS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP10030SWS1
Operation
D Input Signal Monitor Contents (Un005)
Note 1. The vertical 7-segment LED is divided into two segments, upper and lower, which together
Note 2. Refer to 4-4-3 Important Parameters for input signal allocation.
D Output Signal Monitor Contents (Un006)
Note 1. The vertical 7-segment LED is divided into two segments, upper and lower, which together
Note 2. Refer to 4-4-3 Important Parameters for input signal allocation.
D Input Pulse Counter (Un00C) and Feedback Pulse Counter (Un00d) Contents
• Input Pulse Counter (Un00C) and Feedback Pulse Counter (Un00d) monitor values are displayed as
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
Indicator No.
Indicator No.
8-digit hexadecimal (32-bit string data).
comprise one pair to display the ON/OFF status of a single input signal. When an input signal
is OFF (high level), the top LED is lit, and when the signal is ON (low level), the bottom LED is
lit. When the SEN signal is ON (high level), the top LED is lit, and when the signal is OFF (low
level), the bottom LED is lit.
comprise one pair to display the ON/OFF status of a single output signal. When an output
signal is OFF (high level), the top LED is lit, and when the signal is ON (low level), the bottom
LED is lit.
CN1-40
CN1-41
CN1-42
CN1-43
CN1-44
CN1-45
CN1-46
CN1-4
CN1-31, 32
CN1-25, 26
CN1-27, 28
CN1-29, 30
CN1-37
CN1-38
CN1-39
Output terminal
Input terminal
RUN (RUN command)
MING (gain reduction), RDIR (rotation direction command), TVSEL
(control mode switching), PLOCK (position lock command), IPG (pulses
prohibited)
POT (forward rotation prohibited)
NOT (reverse rotation prohibited)
RESET (alarm reset)
PCL (forward rotation current limit), SPD1 (speed selection command 1)
NCL (reverse rotation current limit), SPD2 (speed selection command 2)
SEN (sensor ON)
ALM (alarm)
INP1 (positioning completed output 1), VCMP (speed conformity)
TGON (Servomotor rotation detection)
READY (servo ready)
ALO1 (alarm code output 1)
ALO2 (alarm code output 2)
ALO3 (alarm code output 3)
LED No.
LED No.
Signal name (default)
Signal name (default)
OFF (high level)
(top is lit)
OFF (high level)
(top is lit)
ON (low level)
(bottom is lit)
ON (low level)
(bottom is lit)
Chapter 4
4-125