R88M-WP10030S-WS1 Omron, R88M-WP10030S-WS1 Datasheet - Page 391

no-image

R88M-WP10030S-WS1

Manufacturer Part Number
R88M-WP10030S-WS1
Description
SERVO MOTOR 100W 100V
Manufacturer
Omron
Datasheet

Specifications of R88M-WP10030S-WS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP10030SWS1
Operation
4-11-12 Clearing Option Unit Detection Results
H Option Unit Detection Results Clear (Fn014)
• If an Option Unit is removed and then the power supply is turned ON, an A.E7 alarm (option detection
• If an A.E7 alarm occurs, use one of the following methods to clear the alarm.
D Using an Option Unit
Turn OFF the power supplies, mount the Option Unit properly, and turn ON the power supplies.
D Not Using an Option Unit
Initialize the user parameters (by executing Fn005), clear the Option Unit detection results (by execut-
ing Fn014), and reset the power supplies.
Operation Procedure
Note 1. Perform the above operation when A.E7 is displayed.
Note 2. The digits you can manipulate will flash.
(Approx. 1 s later)
error) will occur. This is because the Servo Driver has determined that an error exists because the
Option Unit cannot be detected.
operation
Option Unit detection re-
sults clear
System Check Mode
PR02W
key operation
Front panel
(1 s min.)
(1 s min.)
Display
1 s min.
1 s min.
Status Display Mode. (See note 1.)
Press the MODE/SET Key to change to System Check
Mode.
Press the Up or Down Key to set function code Fn014.
(See note 2.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to display “o.InIt.”
Press the MODE/SET Key. The Option Unit detection
results will be cleared. When the clear operation is
completed, “donE” will flash for approximately 1 s.
After “donE has been displayed, the display will return to
“o.InIt.”
Press the DATA Key (front panel: DATA Key for 1 s min.)
to return to the System Check Mode function code
display.
(1 s later)
Explanation
Return to o.InIt display.
Display for clearing Option Unit
detection results (o.InIt dis-
played.)
Clear completed
(“donE” flashes).
Execute the clear operation.