UPD78F1506GF-GAT-AX Renesas Electronics America, UPD78F1506GF-GAT-AX Datasheet - Page 593

no-image

UPD78F1506GF-GAT-AX

Manufacturer Part Number
UPD78F1506GF-GAT-AX
Description
MCU 16BIT 78K0R/LX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Lx3r
Datasheet

Specifications of UPD78F1506GF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LCD, LVD, POR, PWM, WDT
Number Of I /o
78
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
<R>
78K0R/Lx3
R01UH0004EJ0401 Rev.4.01
Jul 2, 2010
Caution When bit 3 (TRC) of the IICA status register (IICS) is set to 1, WREL is set to 1 during the
Cautions concerning set timing
• For master reception:
• For master transmission: A stop condition cannot be generated normally during the acknowledge period.
• Cannot be set to 1 at the same time as STT.
• SPT can be set to 1 only when in master mode.
• When WTIM has been cleared to 0, if SPT is set to 1 during the wait period that follows output of eight clocks, note
• Setting SPT to 1 and then setting it again before it is cleared to 0 is prohibited.
Condition for clearing (SPT = 0)
• Cleared by loss in arbitration
• Automatically cleared after stop condition is detected
• Cleared by LREL = 1 (exit from communications)
• When IICE = 0 (operation stop)
• Reset
Remark
that a stop condition will be generated during the high-level period of the ninth clock. WTIM should be changed from
0 to 1 during the wait period following the output of eight clocks, and SPT should be set to 1 during the wait period
that follows the output of the ninth clock.
SPT
0
1
ninth clock and wait is canceled, after which TRC is cleared and the SDA0 line is set to high
impedance. Release the wait performed while the TRC bit is 1 (transmission status) by
writing to the IICA shift register.
Bit 0 (SPT) becomes 0 when it is read after data setting.
Stop condition is not generated.
Stop condition is generated (termination of master device’s transfer).
Figure 15-6. Format of IICA Control Register 0 (IICCTL0) (4/4)
Cannot be set to 1 during transfer.
Can be set to 1 only in the waiting period when ACKE has been cleared to 0 and slave
has been notified of final reception.
Therefore, set it during the wait period that follows output of the ninth clock.
Stop condition trigger
Condition for setting (SPT = 1)
• Set by instruction
CHAPTER 15 SERIAL INTERFACE IICA
593

Related parts for UPD78F1506GF-GAT-AX