LM3S3768 Luminary Micro, Inc, LM3S3768 Datasheet - Page 114

no-image

LM3S3768

Manufacturer Part Number
LM3S3768
Description
Lm3s3768 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet
Reset
Reset
Type
Type
System Control
Sleep Mode Clock Gating Control Register 0 (SCGC0)
Base 0x400F.E000
Offset 0x110
Type R/W, reset 0x00000040
114
Bit/Field
31:21
19:17
15:10
20
16
RO
RO
31
15
0
0
RO
RO
Register 24: Sleep Mode Clock Gating Control Register 0 (SCGC0), offset
0x110
This register controls the clock gating logic. Each bit controls a clock enable for a given interface,
function, or unit. If set, the unit receives a clock and functions. Otherwise, the unit is unclocked and
disabled (saving power). If the unit is unclocked, reads or writes to the unit will generate a bus fault.
The reset state of these bits is 0 (unclocked) unless otherwise noted, so that all functional units are
disabled. It is the responsibility of software to enable the ports necessary for the application. Note
that these registers may contain more bits than there are interfaces, functions, or units to control.
This is to assure reasonable code compatibility with other family and future parts. RCGC0 is the
clock configuration register for running operation, SCGC0 for Sleep operation, and DCGC0 for
Deep-Sleep operation. Setting the ACG bit in the Run-Mode Clock Configuration (RCC) register
specifies that the system uses sleep modes.
30
14
0
0
RO
RO
29
13
reserved
reserved
reserved
0
0
Name
reserved
PWM
ADC
RO
RO
28
12
0
0
RO
RO
27
11
0
0
Type
R/W
R/W
RO
RO
RO
reserved
RO
RO
26
10
0
0
R/W
RO
MAXADCSPD
Reset
25
0
9
0
0
0
0
0
0
Preliminary
R/W
RO
24
0
8
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
PWM Clock Gating Control. This bit controls the clock gating for the
PWM module. If set, the unit receives a clock and functions. Otherwise,
the unit is unclocked and disabled. If the unit is unclocked, a read or
write to the unit generates a bus fault.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
ADC0 Clock Gating Control. This bit controls the clock gating for general
SAR ADC module 0. If set, the unit receives a clock and functions.
Otherwise, the unit is unclocked and disabled. If the unit is unclocked,
a read or write to the unit generates a bus fault.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
reserved
RO
RO
23
0
7
0
R/W
HIB
RO
22
0
6
0
RO
RO
21
0
5
0
reserved
PWM
R/W
RO
20
0
4
0
WDT
R/W
RO
19
0
3
0
reserved
RO
RO
18
0
2
0
reserved
RO
RO
17
0
1
0
June 02, 2008
ADC
R/W
RO
16
0
0
0

Related parts for LM3S3768