LM3S3768 Luminary Micro, Inc, LM3S3768 Datasheet - Page 606

no-image

LM3S3768

Manufacturer Part Number
LM3S3768
Description
Lm3s3768 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet
Pulse Width Modulator (PWM)
19.2
19.2.1
19.2.2
606
Figure 19-2. PWM Module Block Diagram
PWM Clock
Functional Description
PWM Timer
The timer in each PWM generator runs in one of two modes: Count-Down mode or Count-Up/Down
mode. In Count-Down mode, the timer counts from the load value to zero, goes back to the load
value, and continues counting down. In Count-Up/Down mode, the timer counts from zero up to the
load value, back down to zero, back up to the load value, and so on. Generally, Count-Down mode
is used for generating left- or right-aligned PWM signals, while the Count-Up/Down mode is used
for generating center-aligned PWM signals.
The timers output three signals that are used in the PWM generation process: the direction signal
(this is always Low in Count-Down mode, but alternates between Low and High in Count-Up/Down
mode), a single-clock-cycle-width High pulse when the counter is zero, and a single-clock-cycle-width
High pulse when the counter is equal to the load value. Note that in Count-Down mode, the zero
pulse is immediately followed by the load pulse.
PWM Comparators
There are two comparators in each PWM generator that monitor the value of the counter; when
either match the counter, they output a single-clock-cycle-width High pulse. When in Count-Up/Down
mode, these comparators match both when counting up and when counting down; they are therefore
qualified by the counter direction signal. These qualified pulses are used in the PWM generation
process. If either comparator match value is greater than the counter load value, then that comparator
never outputs a High pulse.
Figure 19-3 on page 607 shows the behavior of the counter and the relationship of these pulses
when the counter is in Count-Down mode. Figure 19-4 on page 607 shows the behavior of the counter
and the relationship of these pulses when the counter is in Count-Up/Down mode.
Interrupts /
Triggers
PWM Generator Block
PWMnCOUNT
PWMnLOAD
PWMnCMPA
PWMnCMPB
PWMnCTL
zero
load
dir
cmp A
cmp B
Preliminary
Interrupt and
PWMnINTEN
PWMnGENA
PWMnGENB
Generator
PWMnRIS
PWMnISC
Trigger
PWMnDBRISE
PWMnDBFALL
PWMnDBCTL
June 02, 2008
PWMn_Fault
PWMn_A
PWMn_B
Fault

Related parts for LM3S3768