EP2AGX45DF29I5 Altera, EP2AGX45DF29I5 Datasheet - Page 36

no-image

EP2AGX45DF29I5

Manufacturer Part Number
EP2AGX45DF29I5
Description
IC ARRIA II GX FPGA 45K 780FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX45DF29I5

Number Of Logic Elements/cells
42959
Number Of Labs/clbs
1805
Total Ram Bits
3435
Number Of I /o
364
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX45DF29I5
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX45DF29I5
Manufacturer:
ALTERA
0
Part Number:
EP2AGX45DF29I5N
Manufacturer:
ALTERA
Quantity:
201
Part Number:
EP2AGX45DF29I5N
Manufacturer:
ALTERA
Quantity:
853
Part Number:
EP2AGX45DF29I5N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX45DF29I5N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX45DF29I5N
0
2–8
Figure 2–7. ALM in Normal Mode
Note to
(1) Combinations of functions with fewer inputs than those shown are also supported. For example, combinations of functions with the following
Arria II Device Handbook Volume 1: Device Interfaces and Integration
number of inputs are supported: 4 and 3, 3 and 3, 3 and 2, and 5 and 2.
Figure
datae0
datae1
datae0
datae1
datae0
datae1
dataf0
dataf1
dataf0
dataf1
dataf0
dataf1
dataa
datab
datad
dataa
datab
datad
dataa
datab
datad
datac
datac
datac
2–7:
Normal Mode
Normal mode is suitable for general logic applications and combinational functions.
In this mode, up to eight data inputs from the LAB local interconnect are inputs to the
combinational logic. Normal mode allows two functions to be implemented in one
Arria II ALM, or a single function of up to six inputs. The ALM can support certain
combinations of completely independent functions and various combinations of
functions that have common inputs.
Figure 2–7
Normal mode provides complete backward-compatibility with 4-input LUT
architectures.
3-Input
LUT
4-Input
5-Input
5-Input
4-Input
4-Input
LUT
LUT
LUT
LUT
LUT
(Note 1)
shows the supported LUT combinations in normal mode.
combout0
combout1
combout0
combout1
combout0
combout1
Chapter 2: Logic Array Blocks and Adaptive Logic Modules in Arria II Devices
datae0
datae1
datae0
datae0
datae1
dataf0
dataf1
dataf0
dataf0
dataf1
dataa
datab
datad
dataa
datab
datad
dataa
datab
datad
datac
datac
datac
6-Input
6-Input
6-Input
5-Input
5-Input
LUT
LUT
LUT
LUT
LUT
December 2010 Altera Corporation
Adaptive Logic Modules
combout0
combout1
combout0
combout0
combout1

Related parts for EP2AGX45DF29I5