Timer Control Registers
Table 5. Timer Control Register
Bit
Reset
CPU Access
Note: R = Read Only; R/W = Read/Write.
Bit
Position
7
PRT_IRQ
6
IRQ_EN
5
4
PRT_MODE
[3:2]
CLK_DIV
The Timer Control register can be read or written to. The timer reload registers are Write
Only and are located at the same I/O address as the timer data registers, which are Read
Only.
The Timer Control registers, listed in
including enabling the timer, selecting the clock divider, enabling the interrupt, selecting
between CONTINUOUS and SINGLE PASS modes, and enabling the automatic reload
feature.
0086h, TMR3_CTL = 0089h, TMR4_CTL = 008Ch, TMR5_CTL = 008Fh)
Value
0
1
0
1
0
0
1
00
01
10
11
Description
The timer has not reached its end-of-count value. This bit is
reset to 0 every time the TMRx_CTL register is read.
The timer has reached its end-of-count value. If IRQ_EN is set to
1, an interrupt signal is sent to the CPU. This bit remains 1 until
the TMRx_CTL register is read.
Timer interrupt requests are disabled.
Timer interrupt requests are enabled.
Reserved
The timer operates in SINGLE PASS mode. PRT_EN (bit 0) is
reset to 0, and counting stops when the end-of-count value is
reached.
The timer operates in CONTINUOUS mode. The timer reload
value is written to the counter when the end-of-count value is
reached.
Clock ÷ 2 is the timer input source.
Clock ÷ 4 is the timer input source.
Clock ÷ 8 is the timer input source.
Clock ÷ 16 is the timer input source.
R
7
0
R/W
6
0
(TMR0_CTL = 0080h, TMR1_CTL = 0083h, TMR2_CTL =
R/W
5
0
Table
R/W
5, are used to control operation of the timer,
4
0
R/W
3
0
R/W
2
0
Programmable Reload Timers
Product Specification
R/W
1
0
R/W
0
0
eZ80190