AT32UC3C2256C Atmel Corporation, AT32UC3C2256C Datasheet - Page 900

no-image

AT32UC3C2256C

Manufacturer Part Number
AT32UC3C2256C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT32UC3C2256C

Flash (kbytes)
256 Kbytes
Pin Count
64
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
45
Ext Interrupts
64
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
5
Twi (i2c)
2
Uart
4
Can
2
Lin
4
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
2
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
68
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6 or 4.5 to 5.5
Operating Voltage (vcc)
3.0 to 3.6 or 4.5 to 5.5
Fpu
Yes
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
13
Input Capture Channels
6
Pwm Channels
14
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3C2256C-A2UR
Manufacturer:
Cirrus
Quantity:
48
Part Number:
AT32UC3C2256C-A2UR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C2256C-A2UT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C2256C-A2ZR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C2256C-A2ZT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3C2256C-U
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT32UC3C2256C-Z
Manufacturer:
ATMEL
Quantity:
261
Part Number:
AT32UC3C2256C-Z2UR
Manufacturer:
ATMEL
Quantity:
93
32.6.3.13
32.6.3.14
32.6.3.15
32117C–AVR-08/11
TXOUTI
FIFOCON
Alternate pipe
Data flow error
CRC error
• Multi packet mode for OUT pipes
SW
Figure 32-23. Example of an OUT pipe with two data banks and a bank switching delay
See section
OUT pipe.
The user has the possibility to run sequentially several logical pipes on the same physical pipe.
Before switching pipe, the user should save the pipe context (UPCFGn, UPCONn, UPSTAn,
and the pipe descriptor table).
After switching pipe, the user should restore the pipe context, current bank number, and the cur-
rent data toggle by using the UPCONn.INITDTGL and UPCONn.INITBK bits.
This error exists only for isochronous and interrupt pipes for both IN and OUT directions. It sets
the Errorflow Interrupt (ERRORFI) bit in UPSTAn, which triggers an PnINT interrupt if the Error-
f l o w I n t e r r u p t E n a b l e ( E R R O R F E ) b i t i s o n e . T h e u s e r c a n c h e c k t h e
Pn_CTR_STA_BK0/1.UNDERF and OVERF bits in the pipe descriptor to see which current
bank has been affected.
This error exists only for isochronous IN pipes. It sets the CRC Error Interrupt bit (CRCERRI),
which triggers a PnINT interrupt if the CRC Error Interrupt Enable bit (UPCONn.CRCERRE) is
one.
write data to CPU
• An overflow can occur during an OUT stage if the host attempts to send data from an empty
• An underflow can occur during an IN stage if the device tries to send a packet while the bank
bank. The pipe descriptor Pn_CTR_STA_BK0/1.OVERF points out the bank from which the
OUT data should have originated. If the UPSTAn.ERRORFI bit is cleared and a new
transaction is successful, the Pn_CTR_STA_BK0/1.OVERF bit will be cleared.
is full. Typically this occurs when a CPU is not fast enough. The packet data is not written to
the bank and is lost. The pipe descriptor Pn_CTR_STA_BK0/1.UNDERF points out which
bank the OUT data was destined to. If UPSTAn.UNDERFI is zero and a new successful
transaction occurs, Pn_CTR_STA_BK0/1.UNDERF will be cleared.
BANK 0
”Multi packet mode for IN endpoints” on page 887
SW
OUT
SW
write data to CPU
BANK 1
(bank 0)
DATA
SW
ACK
HW
SW
OUT
and just replace IN endpoints with
write data to CPU
BANK0
(bank 1)
DATA
AT32UC3C
ACK
900

Related parts for AT32UC3C2256C