EVB9S12XEP100 Freescale Semiconductor, EVB9S12XEP100 Datasheet - Page 557

BOARD EVAL FOR MC9S12XEP100

EVB9S12XEP100

Manufacturer Part Number
EVB9S12XEP100
Description
BOARD EVAL FOR MC9S12XEP100
Manufacturer
Freescale Semiconductor
Type
MCUr
Datasheet

Specifications of EVB9S12XEP100

Contents
Module and Misc Hardware
Processor To Be Evaluated
MC9S12XEP100
Data Bus Width
16 bit
Interface Type
RS-232
Silicon Manufacturer
Freescale
Core Architecture
S12
Core Sub-architecture
S12
Silicon Core Number
MC9S12
Silicon Family Name
S12XE
Rohs Compliant
Yes
For Use With/related Products
MC9S12XEP100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
All bits reset to zero.
14.3.2.21 ICPAR — Input Control Pulse Accumulators Register (ICPAR)
Read: Anytime
Write: Anytime.
All bits reset to zero.
The 8-bit pulse accumulators PAC3 and PAC2 can be enabled only if PAEN in PACTL is cleared. If PAEN
is set, PA3EN and PA2EN have no effect.
The 8-bit pulse accumulators PAC1 and PAC0 can be enabled only if PBEN in PBCTL is cleared. If PBEN
is set, PA1EN and PA0EN have no effect.
Freescale Semiconductor
Module Base + 0x0028
Because of an order from the United States International Trade Commission, BGA-packaged product lines and partnumbers
POLF[3:0]
PA[3:0]EN
Reset
MCZF
indicated here currently are not available from Freescale for import or sale in the United States prior to September 2010
Field
Field
3:0
3:0
7
W
R
Modulus Counter Underflow Flag — The flag is set when the modulus down-counter reaches 0x0000.
The flag indicates when interrupt conditions have occurred. The flag can be cleared via the normal flag clearing
mechanism (writing a one to the flag) or via the fast flag clearing mechanism (Reference TFFCA bit in
Section 14.3.2.6, “Timer System Control Register 1
First Input Capture Polarity Status — These are read only bits. Writes to these bits have no effect.
Each status bit gives the polarity of the first edge which has caused an input capture to occur after capture latch
has been read.
Each POLFx corresponds to a timer PORTx input.
0 The first input capture has been caused by a falling edge.
1 The first input capture has been caused by a rising edge.
8-Bit Pulse Accumulator ‘x’ Enable
0 8-Bit Pulse Accumulator is disabled.
1 8-Bit Pulse Accumulator is enabled.
0
0
7
When TFFCA = 1, the flag cannot be cleared via the normal flag clearing
mechanism (writing a one to the flag). Reference
System Control Register 1
Figure 14-44. Input Control Pulse Accumulators Register (ICPAR)
= Unimplemented or Reserved
0
0
6
MC9S12XE-Family Reference Manual Rev. 1.23
Table 14-25. MCFLG Field Descriptions
Table 14-26. ICPAR Field Descriptions
5
0
0
(TSCR1)”.
NOTE
0
0
4
Description
Description
(TSCR1)”).
PA3EN
0
3
Chapter 14 Enhanced Capture Timer (ECT16B8CV3)
Section 14.3.2.6, “Timer
PA2EN
2
0
PA1EN
0
1
PA0EN
0
0
557

Related parts for EVB9S12XEP100