DF2117VLP20V Renesas Electronics America, DF2117VLP20V Datasheet - Page 490

IC H8S/2117 MCU FLASH 145TFLGA

DF2117VLP20V

Manufacturer Part Number
DF2117VLP20V
Description
IC H8S/2117 MCU FLASH 145TFLGA
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheet

Specifications of DF2117VLP20V

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
FIFO, I²C, LPC, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
112
Program Memory Size
160KB (160K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
145-TFLGA
For Use With
HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)3DK2166 - DEV EVAL KIT H8S/2166
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2117VLP20V
Manufacturer:
Renesas
Quantity:
100
Part Number:
DF2117VLP20V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 15 Serial Communication Interface (SCI)
15.6.4
Figure 15.18 shows an example of SCI operation for reception in clocked synchronous mode. In
serial reception, the SCI operates as described below.
1. The SCI performs internal initialization in synchronization with a synchronization clock input
2. If an overrun error (when reception of the next data is completed while the RDRF flag is still
3. If reception finishes successfully, the RDRF bit in SSR is set to 1, and receive data is
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the ORER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 15.19 shows a sample flowchart
for serial data reception.
Rev. 3.00 Sep. 28, 2009 Page 444 of 910
REJ09B0350-0300
Synchronization
clock
Serial data
RDRF
ORER
or output, starts receiving data, and stores the receive data in RSR.
set to 1) occurs, the ORER bit in SSR is set to 1. If the RIE bit in SCR is set to 1 at this time,
an ERI interrupt request is generated. Receive data is not transferred to RDR. The RDRF flag
remains to be set to 1.
transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an RXI interrupt request is
generated. Because the RXI interrupt routine reads the receive data transferred to RDR before
reception of the next receive data has finished, continuous reception can be enabled.
Figure 15.18 Example of SCI Receive Operation in Clocked Synchronous Mode
Serial Data Reception (Clocked Synchronous Mode)
RXI interrupt
request
generated
Bit 7
RDR data read and
RDRF flag cleared to 0
in RXI interrupt service
routine
Bit 0
1 frame
Bit 7
Bit 0
RXI interrupt request
generated
Bit 1
ERI interrupt request
generated by overrun
error
Bit 6
Bit 7