PEF 20954 HT V1.1 Infineon Technologies, PEF 20954 HT V1.1 Datasheet - Page 115

no-image

PEF 20954 HT V1.1

Manufacturer Part Number
PEF 20954 HT V1.1
Description
IC ECHO CANCELLER DGTL TQFP144
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEF 20954 HT V1.1

Function
Smart Integrated Digital Echo Canceller (SIDEC)
Interface
PCM, Serial, UCC
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
350mA
Power (watts)
900mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
144-LFQFP
Includes
Double Talk Detection
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
PEF20954HTV1.1
SP000007505
AVDCI[7:0] (Addr.: 75H): AFI Voice Detection Count Init, write protected,
Reset value = 85H
VDCI[7:0]
ATMAT[3:0] (Addr.: 77H): AFI Turbo Mode Activation Threshold, write protected,
Reset value = 08H
TURBOTH[3:0]
AACSC[7:0] (Addr.: 78H): AFI Auxiliary Coefficient Supervision Configuration,
write protected, Reset value = 00H
To improve handling of periodic signals, two thresholds are used to determine when
- probably due to a periodic signal - most of the auxiliary coefficients are becoming quite
large. In that case, coefficient update should be slowed down. The slow down mode
condition is described by ACSCTH[4:0] and ACSTH[1:0]. The effect of the slow down
mode can be configured via the bit ACSEFFECT.
Data Sheet
EFFECT
VDCI
ACS
[7]
-
ACSC
TH[4]
VDCI
[6]
-
Voice Detection Counter Init value:
A counter is used to count the number of values within the
VDINTERVAL which fulfill the "no-voice"-criterion. "no-voice" is
detected, if the counter ends up with a value that is greater or equal
to 512 (64 ms mode) or 1024 (128 ms mode), respectively. The init
-value for this counter is determined by VDCI in the following way:
64 ms Mode:
128 ms Mode:
The reset value of 85H requires that 48% of the values
must fulfill the "no-voice" criterion in case the default VDINTERVAL
(64 ms) is set)
Turbo Threshold:
This register specifies the threshold for activating the AFI turbo mode
(turbo-on indicates that the AFI is adapting to a new end echo path).
Turbo mode is activated if the absolute value of one or more auxiliary
coefficents is greater than 351 + 4 * TURBOTH.
The default threshold is 383.
ACSC
TH[3]
VDCI
[5]
-
,
ACSC
TH[2]
VDCI
[4]
-
115
<init-value> = VDCI[7..0] * 2
<init-value> = VDCI[7..0] * 4
TURBO
ACSC
VDCI
TH[3]
TH[1]
[3]
TURBO
ACSC
TH[2]
TH[0]
VDCI
[2]
Register Description
TURBO
TH[1]
TH[1]
VDCI
ACS
[1]
Rev. 2, 2004-07-28
PEB 20954
PEF 20954
TURBO
VDCI
TH[0]
TH[0]
ACS
[0]