PEF 20954 HT V1.1 Infineon Technologies, PEF 20954 HT V1.1 Datasheet - Page 72

no-image

PEF 20954 HT V1.1

Manufacturer Part Number
PEF 20954 HT V1.1
Description
IC ECHO CANCELLER DGTL TQFP144
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEF 20954 HT V1.1

Function
Smart Integrated Digital Echo Canceller (SIDEC)
Interface
PCM, Serial, UCC
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
350mA
Power (watts)
900mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
144-LFQFP
Includes
Double Talk Detection
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
PEF20954HTV1.1
SP000007505
Table 31
Register Addr. Value
ATMAT
AACSC modifications mainly prevent misadaptation and divergence on periodical
signals. The effect is not very strong but noticeable. Be careful not to unnecessarily
activate the feature, since its effect on other functions has not been elaborately
evaluated. The strongest setting for the AACSC register would be 84H and should be
avoided. For fine-tuning play with the turbo-threshold. Lowering the turbo-threshold
might increase convergence speed and stability if the auxiliary coefficient supervision
feature is activated.
Table 32
Register
VDFCTRL
AVDDI
AVDHG
Data Sheet
77H
Addr. Value
76H
77H
74H
Auxiliary coefficient supervision (cont’d)
Sinusoidal (non-voice) signal protection
TURBO
ACSEFF
ECT
VDFRELEN
VDFREL
VDFSOL
VDMAXINTER
VAL
VDINTERVAL
VDSODELAY
Mod.
0
1
Up
Down
Mod.
0
1
Up
Down
Up
Down
Up
Down
Up
Down
Up
Effect
stability "Down", convergence speed "Up", if
ACSCTH > 0
stability "Up", convergence speed "Down", if
ACSCTH > 0
stability "Down", if AACSC.ACSCTH > 0
stability "Up", if AACSC.ACSCTH > 0
72
Effect
stability "Down", ERLE "Up"
stability "Down", ERLE "Up", if
stability "Down", convergence speed
stability "Up", ERLE "Down",
VDFRELEN = 1
stability "Up", ERLE "Down", if
VDFRELEN = 1
stability "Down", ERLE "Up"
stability "Up", ERLE "Down"
stability "Down", convergence speed
"Up", if activated
stability "Up", convergence speed
"Down", if activated
"Up", if activated
stability "Up", convergence speed
"Down", if activated
stability "Up", convergence speed
"Down", if activated