TMP92xy22FG Toshiba, TMP92xy22FG Datasheet - Page 202

no-image

TMP92xy22FG

Manufacturer Part Number
TMP92xy22FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP92xy22FG

Package
LQFP100
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
32
Architecture
32-bit CISC
Usb/spi Channels
-
Uart/sio Channels
2
I2c/sio Bus Channels
1
(s)dram Controller
-
Adc 10-bit Channel
8
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
2
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
-
Number Of I/o Ports
50
Power Supply Voltage(v)
3.0 to 3.6
ADMOD0
(12B8H)
3.11.1
Bit symbol
Read/Write
After reset
Function
Analog/Digital Converter Registers
ADMOD1, and ADMOD2. The eight AD conversion data result registers (ADREG0H/L to
ADREG7H/L) store the results of AD conversion.
The AD converter is controlled by the three AD mode control registers: ADMOD0,
Figure 3.11.2 shows the registers related to the AD converter.
AD
conversion
end flag
0: Conversion
1: Conversion
in progress
complete
EOCF
7
0
R
AD
conversion
busy flag
0: Conversion
1: Conversion
Figure 3.11.2 Register for AD Converter
stopped
in progress
ADBF
6
0
AD Mode Control Register 0
Always
write “0”.
92CM22-200
5
0
Always
write “0”.
4
0
Interrupt
specification
in
conversion
channel
fixed repeat
mode
0: Every
1: Every
conversion
fourth
conversion
ITM0
3
0
Note: Always read as 0.
AD conversion in progress
AD conversion start
AD scan mode setting
AD repeat mode setting
Specify AD conversion interrupt for
channel fixed repeat conversion mode
AD conversion busy flag
0
1
0
1
0
1
0
1
0
1
0
1
R/W
Don’t care
Start AD conversion.
AD conversion channel fixed mode
AD conversion channel scan mode
AD single conversion mode
AD repeat conversion mode
Channel fixed repeat conversion mode
<SCAN> = “0”, <REPEAT> = “1”
Generates interrupt every conversion.
Generates interrupt every fourth
conversion.
AD conversion stopped
AD conversion in progress
Before or during AD conversion
AD conversion complete
Repeat
mode
specification
0: Single
1: Repeat
REPEAT
conversion
conversion
mode
2
0
Scan mode
specification
0: Conversion
1: Conversion
channel
fixed mode
channel
scan mode
SCAN
1
0
TMP92CM22
2007-02-16
AD
conversion
start
0: Don’t care
1: Start
Always 0 when
read.
conversion
ADS
0
0

Related parts for TMP92xy22FG