C8051F581-IMR Silicon Labs, C8051F581-IMR Datasheet - Page 285

no-image

C8051F581-IMR

Manufacturer Part Number
C8051F581-IMR
Description
8-bit Microcontrollers - MCU 50MIPS 128kB 8kB SPI
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F581-IMR

Rohs
yes
Core
8051
Processor Series
C8051
Data Bus Width
8 bit
27.1. Timer 0 and Timer 1
Each timer is implemented as a 16-bit register accessed as two separate bytes: a low byte (TL0 or TL1)
and a high byte (TH0 or TH1). The Counter/Timer Control register (TCON) is used to enable Timer 0 and
Timer 1 as well as indicate status. Timer 0 interrupts can be enabled by setting the ET0 bit in the IE regis-
ter (Section “14.2. Interrupt Register Descriptions” on page 129); Timer 1 interrupts can be enabled by set-
ting the ET1 bit in the IE register (Section “14.2. Interrupt Register Descriptions” on page 129). Both
counter/timers operate in one of four primary modes selected by setting the Mode Select bits T1M1 – T0M0
in the Counter/Timer Mode register (TMOD). Each timer can be configured independently. Each operating
mode is described below.
27.1.1. Mode 0: 13-bit Counter/Timer
Timer 0 and Timer 1 operate as 13-bit counter/timers in Mode 0. The following describes the configuration
and operation of Timer 0. However, both timers operate identically, and Timer 1 is configured in the same
manner as described for Timer 0.
The TH0 register holds the eight MSBs of the 13-bit counter/timer. TL0 holds the five LSBs in bit positions
TL0.4 – TL0.0. The three upper bits of TL0 (TL0.7 – TL0.5) are indeterminate and should be masked out or
ignored when reading. As the 13-bit timer register increments and overflows from 0x1FFF (all ones) to
0x0000, the timer overflow flag TF0 (TCON.5) is set and an interrupt will occur if Timer 0 interrupts are
enabled.
The C/T0 bit (TMOD.2) selects the counter/timer's clock source. When C/T0 is set to logic 1, high-to-low
transitions at the selected Timer 0 input pin (T0) increment the timer register (Refer to Section
“20.3. Priority Crossbar Decoder” on page 190 for information on selecting and configuring external I/O
pins). Clearing C/T selects the clock defined by the T0M bit (CKCON.3). When T0M is set, Timer 0 is
clocked by the system clock. When T0M is cleared, Timer 0 is clocked by the source selected by the Clock
Scale bits in CKCON (see SFR Definition 27.1).
Setting the TR0 bit (TCON.4) enables the timer when either GATE0 (TMOD.3) is logic 0 or the input signal
INT0 is active as defined by bit IN0PL in register IT01CF (see SFR Definition 14.7). Setting GATE0 to 1
allows the timer to be controlled by the external input signal INT0 (see Section “14.2. Interrupt Register
Descriptions” on page 129), facilitating pulse width measurements.
Setting TR0 does not force the timer to reset. The timer registers should be loaded with the desired initial
value before the timer is enabled.
TL1 and TH1 form the 13-bit register for Timer 1 in the same manner as described above for TL0 and TH0.
Timer 1 is configured and controlled using the relevant TCON and TMOD bits just as with Timer 0. The
input signal INT1 is used with Timer 1; the INT1 polarity is defined by bit IN1PL in register IT01CF (see
SFR Definition 14.7).
Note: X = Don't Care
TR0
0
1
1
1
GATE0
X
0
1
1
Rev. 1.2
INT0
X
X
0
1
Counter/Timer
C8051F58x/F59x
Disabled
Disabled
Enabled
Enabled