5.1.3
The MCU contains a watchdog timer which automatically times out unless it is reset within a specific
time by a program reset sequence. If the COP watchdog timer is allowed to timeout, a reset is
generated which drives the RESET pin low to reset the MCU and the external system.
The COP reset function can be enabled by programming the NOCOP control bit in the system
configuration register (CONFIG). Once programmed, this control bit remains set (or cleared), even
when no power is applied, and the COP function is enabled or disabled independent of resident
software. Protected control bits CR0 and CR1 in the configuration options register (OPTION) allow
the user to select one of four COP timeout periods. Table 5-1 shows the relationship between CR0
and CR1 and the timeout period for various system clock frequencies.
The sequence for resetting the watchdog timer is as follows:
Both writes must occur in this sequence prior to the timeout, but any number of instructions can be
executed between the two writes.
5.1.4
The MCU contains a clock monitor circuit which measures the E-clock frequency. The clock monitor
function is enabled by the CME control bit in the OPTION register. Upon detection of a slow or absent
clock, the clock monitor circuit (if enabled by CME = 1) will cause a system reset to be generated.
If the E-clock input rate is above approximately 200 kHz, then the clock monitor does not generate
a reset. If the E-clock is lost or its frequency falls below 10 kHz, then a reset is generated, and the
RESET pin is driven low to reset the external system.
MOTOROLA
5-2
CR1 CR0
0
0
1
1
0
1
0
1
Computer Operating Properly (COP) Reset
Clock Monitor Reset
1) Write $55 to the COP reset register (COPRST)
2) Write $AA to the COP reset register (COPRST)
Divided
E 2
By
E =
16
64
1
4
15
– 0 / +15.6 ms
XTAL = 2
15.625 ms
Timeout
2.1 MHz
62.5 ms
250 ms
RESETS, INTERRUPTS AND LOW POWER MODES
1 s
23
Table 5-1. COP Timeout Periods
XTAL = 8.0 MHz
– 0 / +16.4 ms
16.384 ms
65.536 ms
262.14 ms
Timeout
2.0 MHz
1.049 s
– 0 / +26.7 ms
4.9152 MHz
1.2288 MHz
26.667 ms
106.67 ms
426.67 ms
Timeout
XTAL =
1.707 s
XTAL = 4.0 MHz
– 0 / +32.8 ms
32.768 ms
131.07 ms
524.29 ms
Timeout
1.0 MHz
2.1 s
– 0 / +35.6 ms
3.6864 MHz
35.556 ms
142.22 ms
568.89 ms
MC68HC11G5
921.6 kHz
Timeout
XTAL =
2.276 s