DS72030W200FPV Renesas Electronics America, DS72030W200FPV Datasheet - Page 481

no-image

DS72030W200FPV

Manufacturer Part Number
DS72030W200FPV
Description
MPU, 32BIT, SH7203, ROMLESS, 240QFP
Manufacturer
Renesas Electronics America
Series
SH7200r
Datasheet

Specifications of DS72030W200FPV

Core Size
32bit
Program Memory Size
32KB
Cpu Speed
200MHz
Digital Ic Case Style
QFP
No. Of Pins
240
Supply Voltage Range
1.1V To 1.3V
Operating Temperature Range
-20°C To +85°C
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
This LSI has an on-chip multi-function timer pulse unit 2 (MTU2) that comprises five 16-bit timer
channels.
11.1
• Maximum 16 pulse input/output lines
• Selection of eight counter input clocks for each channel
• The following operations can be set:
• Buffer operation settable for channels 0, 3, and 4
• Phase counting mode settable independently for each of channels 1 and 2
• Cascade connection operation
• Fast access via internal 16-bit bus
• 28 interrupt sources
• Automatic transfer of register data
• A/D converter start trigger can be generated
• Module standby mode can be settable
• A total of six-phase waveform output, which includes complementary PWM output, and
• AC synchronous motor (brushless DC motor) drive mode using complementary PWM output
• In complementary PWM mode, interrupts at the crest and trough of the counter value and A/D
⎯ Waveform output at compare match
⎯ Input capture function
⎯ Counter clear operation
⎯ Multiple timer counters (TCNT) can be written to simultaneously
⎯ Simultaneous clearing by compare match and input capture is possible
⎯ Register simultaneous input/output is possible by synchronous counter operation
⎯ A maximum 12-phase PWM output is possible in combination with synchronous operation
positive and negative phases of reset PWM output by interlocking operation of channels 3 and
4, is possible.
and reset PWM output is settable by interlocking operation of channels 0, 3, and 4, and the
selection of two types of waveform outputs (chopping and level) is possible.
converter start triggers can be skipped.
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Features
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Rev. 3.00 Sep. 28, 2009 Page 449 of 1650
REJ09B0313-0300

Related parts for DS72030W200FPV