LPC1767FBD100,551 NXP Semiconductors, LPC1767FBD100,551 Datasheet - Page 386

IC ARM CORTEX MCU 512K 100-LQFP

LPC1767FBD100,551

Manufacturer Part Number
LPC1767FBD100,551
Description
IC ARM CORTEX MCU 512K 100-LQFP
Manufacturer
NXP Semiconductors
Series
LPC17xxr

Specifications of LPC1767FBD100,551

Core Processor
ARM® Cortex-M3™
Core Size
32-Bit
Speed
100MHz
Connectivity
Ethernet, I²C, IrDA, Microwire, SPI, SSI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, I²S, Motor Control PWM, POR, PWM, WDT
Number Of I /o
70
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.4 V ~ 3.6 V
Data Converters
A/D 8x12b, D/A 1x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-LQFP
Processor Series
LPC17
Core
ARM Cortex M3
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2, MCB1760, MCB1760U, MCB1760UME
For Use With
622-1005 - USB IN-CIRCUIT PROG ARM7 LPC2K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
568-4967
935289808551

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC1767FBD100,551
Quantity:
9 999
Part Number:
LPC1767FBD100,551
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
UM10360
User manual
16.16.2.1 FullCAN message interrupt enable bit
16.16.2 FullCAN interrupts
The CAN Gateway Block contains a 2 kB ID Look-up Table RAM. With this size a
maximum number of 146 FullCAN objects can be defined if the whole Look-up Table RAM
is used for FullCAN objects only. Only the first 64 FullCAN objects can be configured to
participate in the interrupt scheme. It is still possible to define more than 64 FullCAN
objects. The only difference is, that the remaining FullCAN objects will not provide a
FullCAN interrupt.
The FullCAN Interrupt Register-set contains interrupt flags (IntPndx) for (pending)
FullCAN receive interrupts. As soon as a FullCAN message is received, the according
interrupt bit (IntPndx) in the FCAN Interrupt Register gets asserted. In case that the Global
FullCAN Interrupt Enable bit is set, the FullCAN Receive Interrupt is passed to the
Vectored Interrupt Controller.
Application Software has to solve the following:
The software that covers the interrupt priority handling has to assign a receive interrupt
priority to every FullCAN object. If more than one interrupt is pending, then the software
has to decide, which received FullCAN object has to be served next.
To each FullCAN object a new FullCAN Interrupt Enable bit (FCANIntxEn) is added, so
that it is possible to enable or disable FullCAN interrupts for each object individually. The
new Message Lost flag (MsgLstx) is introduced to indicate whether more than one
FullCAN message has been received since last time this message object was read by the
CPU. The Interrupt Enable and the Message Lost bits reside in the existing Look-up Table
RAM.
In
FullCAN, Section. The new introduced FullCAN Message Interrupt enable bit can be used
to enable for each FullCAN message an Interrupt.
1. Index/Object number calculation based on the bit position in the FCANIC Interrupt
2. Interrupt priority handling if more than one FullCAN receive interrupt is pending.
Figure 63
Register for more than one pending interrupt.
8 FullCAN Identifiers with their Source CAN Channel are defined in the
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 19 August 2010
Chapter 16: LPC17xx CAN1/2
UM10360
© NXP B.V. 2010. All rights reserved.
386 of 840