Specifications of EZ80F91AZ050EG

Core Processor
Z8
Core Size
8-Bit
Speed
50MHz
Connectivity
Ethernet, I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
144-LQFP
Processor Series
EZ80F91x
Core
eZ80
Data Bus Width
8 bit
Data Ram Size
16 KB
Interface Type
I2C, IrDA, SPI, UART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
32
Number Of Timers
4
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Development Tools By Supplier
eZ80F910300ZCOG
Minimum Operating Temperature
- 40 C
For Use With
269-4712 - KIT DEV ENCORE 32 SERIES269-4671 - BOARD ZDOTS SBC Z80ACCLAIM PLUS269-4561 - KIT DEV FOR EZ80F91 W/C-COMPILER269-4560 - KIT DEV FOR EZ80F91 W/C-COMPILER
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
 Details
Other names
269-3867
EZ80F91AZ050EG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZ80F91AZ050EG
Manufacturer:
Zilog
Quantity:
10 000
eZ80F91 MCU
Product Specification
236
ZDI Write Operations
ZDI Single-Byte Write
For single-byte Write operations, the address and write control bit are first written to the
ZDI block. Following the single-bit byte separator, the data is shifted into the ZDI block
on the next 8 rising edges of ZCL. The master terminates activity after 8 clock cycles.
Figure 53
displays the timing for ZDI single-byte Write operations.
ZDI Data Byte
ZCL
7
8
9
1
2
3
4
5
6
7
8
9
ZDA
A0
Write
0/1
D7
D6
D5
D4
D3
D2
D1
D0
1
msb
lsb
of DATA
of DATA
lsb of
Single-Bit
End of Data
ZDI Address
Byte Separator
or New ZDI
START Signal
Figure 53. ZDI Single-Byte Data Write Timing
ZDI Block Write
The block Write operation is initiated in the same manner as the single-byte Write opera-
tion, but instead of terminating the Write operation after the first data byte is transferred,
the ZDI master continues to transmit additional bytes of data to the ZDI slave on the
eZ80F91 device. After the receipt of each byte of data the ZDI register address increments
by 1. If the ZDI register address reaches the end of the Write Only ZDI register address
space (
), the address stops incrementing.
Figure 54
displays the timing for ZDI block
30h
Write operations.
PS019215-0910
Zilog Debug Interface