5
5-3 Axis Parameters
5-49
Synchronous Unit Operation Function Setting
Synchronous
Group Stop
Selection
Parameter name
Position Error Limit Value
Synchronous Group Stop Selection
Set the position error amount you want to monitor.
Synchronous Data Refresh areas are allocated to the I/O areas 1,200 to 1,295 words in the
CPU.
You can set the CPU and PCUs, respectively, to exchange data between the CPU and the
allocated areas of each PCU.
For details on synchronous unit operation, refer to Chapter 10, Synchronous Unit Operation Function.
Synchronous group stop selection supports bits 00 to 14 in the Synchronous Data Refresh
area 1,200 words. Select whether or not to stop axis movement when each bit turns ON.
The synchronous group stop selection become valid at power supply ON, restart, or setup.
Bit
00
01
02
03
04
05
Select the operation that takes place when bit 00
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 00.
1: Stop when bit 00 turns ON.
Select the operation that takes place when bit 01
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 01.
1: Stop when bit 01 turns ON.
Select the operation that takes place when bit 02
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 02.
1: Stop when bit 02 turns ON.
Select the operation that takes place when bit 03
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 03.
1: Stop when bit 03 turns ON.
Select the operation that takes place when bit 04
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 04.
1: Stop when bit 04 turns ON.
Select the operation that takes place when bit 05
turns ON in the Synchronous Data Refresh area
1,200 word.
0: Ignore ON of bit 05.
1: Stop when bit 05 turns ON.
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Function
Setting
range
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
Default
values
0
0
0
0
0
0