CJ1W-NC214 Omron, CJ1W-NC214 Datasheet - Page 517

no-image

CJ1W-NC214

Manufacturer Part Number
CJ1W-NC214
Description
High Speed Pulse Train 2 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC214

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
No.
60
61
62
63
Position shift
(Continued)
Pausing and
then
restarting
memory
operation
results in the
operation
started from
the
beginning,
not from the
paused point.
Problem
Malfunction due to
noise from a welder,
Frequency Inverters,
etc.
Operation command
outputs to the driver
turn OFF during
operation.
Mechanical shift
"Sequence No.
Enable" is ON when
"Start" is turned ON at
the restart.
Probable cause
Check if a welder,
Frequency Inverters or
other similar equipment
is located nearby.
Confirm that operation
command outputs to the
driver do not turn OFF
during operation.
Check if dimensional
shifts accumulated
(mark the mechanical
connections to check for
shifting).
Check the ladder
program or data tracing
result.
Item to check
Isolate from any nearby
welder, Frequency
Inverters, etc.
Make sure that
operation command
outputs turn ON at the
correct timings.
Securely tighten the
mechanical tightening
points.
To continue the
operation from the
paused point, turn OFF
"Sequence No. Enable"
when you turn ON
"Start" at restart.
Countermeasure
12-1 Troubleshooting
Confirm
12-8
12

Related parts for CJ1W-NC214