s3c4510b Samsung Semiconductor, Inc., s3c4510b Datasheet - Page 73

no-image

s3c4510b

Manufacturer Part Number
s3c4510b
Description
16/32-bit Risc Microcontroller
Manufacturer
Samsung Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s3c4510b01-QE80
Manufacturer:
BOURNS
Quantity:
400 000
Part Number:
s3c4510b01-QE80
Manufacturer:
SUNMNG
Quantity:
853
Part Number:
s3c4510b01-QE80
Manufacturer:
SAMSUNG
Quantity:
8 000
Part Number:
s3c4510b01-QER0
Manufacturer:
AMCC
Quantity:
156
Part Number:
s3c4510b01-QER0
Manufacturer:
SAMSUMG
Quantity:
20 000
Company:
Part Number:
s3c4510b01-QER0
Quantity:
58
Part Number:
s3c4510b01-QERO
Manufacturer:
Panasonic
Quantity:
12 000
Part Number:
s3c4510b01-QERO
Manufacturer:
SAMSUNG
Quantity:
16 615
S3C4510B
INSTRUCTION SET
USE OF R15
Write-back must not be specified if R15 is specified as the base register (Rn). When using R15 as the base
register you must remember it contains an address 8 bytes on from the address of the current instruction.
R15 must not be specified as the register offset (Rm).
When R15 is the source register (Rd) of a register store (STR) instruction, the stored value will be address of the
instruction plus 12.
RESTRICTION ON THE USE OF BASE REGISTER
When configured for late aborts, the following example code is difficult to unwind as the base register, Rn, gets
updated before the abort handler starts. Sometimes it may be impossible to calculate the initial value.
After an abort, the following example code is difficult to unwind as the base register, Rn, gets updated before the
abort handler starts. Sometimes it may be impossible to calculate the initial value.
Example:
LDR
R0,[R1],R1
Therefore a post-indexed LDR or STR where Rm is the same register as Rn should not be used.
DATA ABORTS
A transfer to or from a legal address may cause problems for a memory management system. For instance, in a
system which uses virtual memory the required data may be absent from main memory. The memory manager
can signal a problem by taking the processor ABORT input HIGH whereupon the data abort trap will be taken. It
is up to the system software to resolve the cause of the problem, then the instruction can be restarted and the
original program continued.
INSTRUCTION CYCLE TIMES
Normal LDR instructions take 1S + 1N + 1I and LDR PC take 2S + 2N +1I incremental cycles, where S,N and I
are defined as sequential (S-cycle), non-sequential (N-cycle), and internal (I-cycle), respectively. STR instructions
take 2N incremental cycles to execute.
3-31