h8s-2161b Renesas Electronics Corporation., h8s-2161b Datasheet - Page 453

no-image

h8s-2161b

Manufacturer Part Number
h8s-2161b
Description
Renesas 16-bit Single-chip Microcomputer H8s Family/h8s/2100 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet
[3]
No
No
Read receive data in RDR and
clear RDRF flag in SSR to 0
Clear ORER flag in SSR to 0
Read ORER flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Overrun error processing
All data received?
Error processing
Start reception
Initialization
Figure 15.19 Sample Serial Reception Flowchart
ORER = 1
RDRF = 1
<End>
<End>
Yes
Yes
No
(Continued below)
Error processing
Section 15 Serial Communication Interface (SCI and IrDA)
Yes
[2]
[1]
[3]
[4]
[5]
[1] SCI initialization:
[2] [3] Receive error processing:
[4] SCI status check and receive data
[5] Serial reception continuation
Rev. 3.00 Mar 21, 2006 page 399 of 788
The RxD pin is automatically
designated as the receive data input
pin.
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
processing, clear the ORER flag to 0.
Transfer cannot be resumed if the
ORER flag is set to 1.
read:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and clear the RDRF flag
to 0.
Transition of the RDRF flag from 0 to 1
can also be identified by an RXI
interrupt.
procedure:
To continue serial reception, before
the MSB (bit 7) of the current frame is
received, reading the RDRF flag,
reading RDR, and clearing the RDRF
flag to 0 should be finished.
However, the RDRF flag is cleared
automatically when the DTC is
initiated by a receive data full interrupt
(RXI) and reads data from RDR.
REJ09B0300-0300