11.8.4
• When making a transition to a mode (Normal, PWM1, PWM2, PCM) in which the pin output
• In PWM mode 1, since a waveform is not output to the TIOC*B (TIOC *D) pin, setting TIOR
• In PWM mode 2, since a waveform is not output to the cycle register pin, setting TIOR will
• In normal mode or PWM mode 2, if TGRC and TGRD operate as buffer registers, setting
• In PWM mode 1, if either TGRC or TGRD operates as a buffer register, setting TIOR will not
• When making a transition to a mode (CPWM, RPWM) in which the pin output level is
Note: Channel number is substituted for * indicated in this article.
Pin initialization procedures are described below for the numbered combinations in table 11.43.
The active level is assumed to be low.
Rev.4.00 Mar. 27, 2008 Page 338 of 882
REJ09B0108-0400
level is selected by the timer I/O control register (TIOR) setting, initialize the pins by means of
a TIOR setting.
will not initialize the pins. If initialization is required, carry it out in normal mode, then switch
to PWM mode 1.
not initialize the pins. If initialization is required, carry it out in normal mode, then switch to
PWM mode 2.
TIOR will not initialize the buffer register pins. If initialization is required, clear buffer mode,
carry out initialization, then set buffer mode again.
initialize the TGRC pin. To initialize the TGRC pin, clear buffer mode, carry out initialization,
then set buffer mode again.
selected by the timer output control register (TOCR) setting, switch to normal mode and
perform initialization with TIOR, then restore TIOR to its initial value, and temporarily disable
channel 3 and 4 output with the timer output master enable register (TOER). Then operate the
unit in accordance with the mode setting procedure (TOCR setting, TMDR setting, TOER
setting).
Multi-Function Timer Pulse Unit (MTU)
Overview of Initialization Procedures and Mode Transitions in Case of Error