HD6417144 RENESAS [Renesas Technology Corp], HD6417144 Datasheet - Page 525

no-image

HD6417144

Manufacturer Part Number
HD6417144
Description
32-Bit RISC Microcomputer SuperHTM RISC engine Family/SH7144 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417144F50V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417144FW50V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Note:
Bit
1
Bit Name Initial Value R/W
IRIC
*
Only 0 can be written to clear the flag.
0
R/(W)* •
Description
[Clearing conditions]
(This may not be a clearing condition. For details, see the
following operation description on DTC.)
I
When a slave address (SVA or SVAX) matches (i.e.,
when the AAS or AASX flag is set to 1), and at the
end of data transfer up to the subsequent
retransmission start condition or stop condition
detection (i.e., at the rising edge of the 9th cycle of
transmission or receive clock)
When the general call address has been detected
(i.e., when 0 is received for R/W and the ADZ flag is
set to 1) and at the end of data reception up to the
subsequent retransmission start condition or stop
condition detection (i.e., at the rising edge of the 9th
cycle of receive clock)
When the ACKE bit is 1, and 1 is received as an
acknowledge bit
(i.e., when the ACKB bit is set to 1)
When the stop condition is detected while the
STOPIM bit is 0
(i.e., when the STOP or the ESTP flag is set to 1)
Synchronous serial format
When the transfer of data has been completed
(i.e., at the rising edge of the 8th transmit/receive
clock)
When a start condition is detected with serial format
When a condition occurs in which the ICDRE or
ICDRF flag is set to 1 in any operating mode.
When a start condition is detected in transmit mode
(i.e., when a start condition is detected and the
ICDRE flag is set to 1 in transmit mode)
When transmitting the data in the ICDR register buffer
(i.e., when data is transferred from ICDRT to ICDDRS
in transmit mode and the ICDRE flag is set to 1, or
data is transferred from ICDRS to ICDRR in receive
mode and the ICDRF flag is set to 1.)
When 0 is written in IRIC after reading IRIC = 1
When ICDR is read or written to by DTC
2
C bus format in the slave mode
Rev.4.00 Mar. 27, 2008 Page 481 of 882
14. I
2
C Bus Interface (IIC) Option
REJ09B0108-0400

Related parts for HD6417144