MPC8544DS Freescale Semiconductor, MPC8544DS Datasheet - Page 241

BOARD DEVELOPMENT SYSTEM 8544

MPC8544DS

Manufacturer Part Number
MPC8544DS
Description
BOARD DEVELOPMENT SYSTEM 8544
Manufacturer
Freescale Semiconductor
Series
PowerQUICC III™r
Type
MPUr
Datasheets

Specifications of MPC8544DS

Contents
Board
Processor To Be Evaluated
MPC8544E
Data Bus Width
32 bit
Interface Type
Ethernet, I2C
Operating Supply Voltage
- 0.3 V to + 1.1 V
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
For Use With/related Products
MPC8544
For Use With
PPC8544EVTANG - EVAL MPC8544 783FCPBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6.9
6.9.1
6.9.2
Freescale Semiconductor
Reset
Reset
32–61
62–63
32–61
SPR 513
SPR 514
Bits
Bits
62
63
W
R
W
R
32
32
target address
entry address
Branch buffer
Branch buffer
Branch Target Buffer (BTB) Registers
IAB[0–1]
BDIRPR
Name
Name
IAB2
Branch Buffer Entry Address Register (BBEAR)
Branch Buffer Target Address Register (BBTAR)
MPC8544E PowerQUICC III Integrated Host Processor Family Reference Manual, Rev. 1
Figure 6-30. Branch Buffer Target Address Register (BBTAR)
Figure 6-29. Branch Buffer Entry Address Register (BBEAR)
Branch buffer entry effective address bits 0–29
Instruction after branch (with BBTAR[62]). 3-bit pointer that points to the instruction in the cache line
after the branch. See the description in the bblels instruction in the EREF. If the branch is the last
instruction in the cache block, IAB = 000, to indicate the next sequential instruction, which resides in
the zeroth position of the next cache block.
Branch buffer target effective address bits 0–29
Instruction after branch bit 2 (with BBEAR[62–63]). IAB is a 3-bit pointer that points to the instruction
in the cache line after the branch. See the description for bblels in the EREF. If the branch is the last
instruction in the cache block, IAB = 000, to indicate the next sequential instruction, which resides in
the zeroth position of the next cache block.
Branch direction prediction. The user can pick the direction of the predicted branch.
0 The locked address is always predicted as not taken.
1 The locked address is always predicted as taken.
Table 6-15. BBEAR Field Descriptions
Table 6-16. BBTAR Field Descriptions
Branch buffer target address
Branch buffer entry address
All zeros
All zeros
Description
Description
Access: User read/write
Access: User read/write
Core Register Summary
61
IAB2 BDIRPR
62
61
IAB[0–1]
62
63
6-23
63