AT90CAN32 Automotive Atmel Corporation, AT90CAN32 Automotive Datasheet - Page 119

no-image

AT90CAN32 Automotive

Manufacturer Part Number
AT90CAN32 Automotive
Description
Manufacturer
Atmel Corporation

Specifications of AT90CAN32 Automotive

Flash (kbytes)
32 Kbytes
Pin Count
64
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
53
Ext Interrupts
8
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Can
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
2
Eeprom (bytes)
1024
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 125
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
4
Output Compare Channels
8
Input Capture Channels
2
Pwm Channels
7
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
13.3.2
13.4
7682C–AUTO–04/08
Timer/Counter Clock Sources
Reusing the Temporary High Byte Register
The following code examples show how to do an atomic write of the TCNTn Register contents.
Writing any of the OCRnx or ICRn Registers can be done by using the same principle.
Note:
The assembly code example requires that the r17:r16 register pair contains the value to be writ-
ten to TCNTn.
If writing to more than one 16-bit register where the high byte is the same for all registers written,
then the high byte only needs to be written once. However, note that the same rule of atomic
operation described previously also applies in this case.
The Timer/Counter can be clocked by an internal or an external clock source. The clock source
is selected by the Clock Select logic which is controlled by the Clock Select (CSn2:0) bits
located in the Timer/Counter control Register B (TCCRnB). For details on clock sources and
prescaler, see
Assembly Code Example
C Code Example
TIM16_WriteTCNTn:
void TIM16_WriteTCNTn(unsigned int i)
{
}
; Save global interrupt flag
in
; Disable interrupts
cli
; Set TCNTn to r17:r16
sts
sts
; Restore global interrupt flag
out
ret
unsigned char sreg;
unsigned int i;
/* Save global interrupt flag */
sreg = SREG;
/* Disable interrupts */
_CLI();
/* Set TCNTn to i */
TCNTn = i;
/* Restore global interrupt flag */
SREG = sreg;
1. The example code assumes that the part specific header file is included.
“Timer/Counter3/1/0 Prescalers” on page
r18,SREG
TCNTnH,r17
TCNTnL,r16
SREG,r18
(1)
(1)
96.
AT90CAN32/64/128
119