AT90CAN32 Automotive Atmel Corporation, AT90CAN32 Automotive Datasheet - Page 252

no-image

AT90CAN32 Automotive

Manufacturer Part Number
AT90CAN32 Automotive
Description
Manufacturer
Atmel Corporation

Specifications of AT90CAN32 Automotive

Flash (kbytes)
32 Kbytes
Pin Count
64
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
53
Ext Interrupts
8
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Can
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
2
Eeprom (bytes)
1024
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 125
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
4
Output Compare Channels
8
Input Capture Channels
2
Pwm Channels
7
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
19.10.2
252
AT90CAN32/64/128
CAN General Status Register - CANGSTA
• Bit 0 – SWRES: Software Reset Request
This auto resettable bit only resets the CAN controller.
• Bit 7 – Reserved Bit
This bit is reserved for future use.
• Bit 6 – OVFG: Overload Frame Flag
This flag does not generate an interrupt.
• Bit 5 – Reserved Bit
This bit is reserved for future use.
• Bit 4 – TXBSY: Transmitter Busy
This flag does not generate an interrupt.
• Bit 3 – RXBSY: Receiver Busy
This flag does not generate an interrupt.
• Bit 2 – ENFG: Enable Flag
This flag does not generate an interrupt.
Initial Value
Read/Write
Bit
– 0 - standby mode: the on-going communication is normally terminated and the CAN
– 1 - enable mode: the CAN channel enters in enable mode once 11 recessive bits has
– 0 - no reset
– 1 - reset: this reset is “ORed” with the hardware reset.
– 0 - no overload frame.
– 1 - overload frame: set by hardware as long as the produced overload frame is sent.
– 0 - transmitter not busy.
– 1 - transmitter busy: set by hardware as long as a frame (data, remote, overload or
– 0 - receiver not busy
– 1 - receiver busy: set by hardware as long as a frame is received or monitored.
– 0 - CAN controller disable: because an enable/standby command is not immediately
– 1 - CAN controller enable.
channel is frozen (the CONMOB bits of every MOb do not change). The transmitter
constantly provides a recessive level. In this mode, the receiver is not enabled but all the
registers and mailbox remain accessible from CPU.
been read.
error frame) or an ACK field is sent. Also set when an inter frame space is sent.
effective, this status gives the true state of the chosen mode.
7
-
-
-
OVFG
R
6
0
5
-
-
-
TXBSY
R
4
0
RXBSY
R
3
0
ENFG
2
R
0
BOFF
R
1
0
ERRP
R
0
0
CANGSTA