AT90CAN32 Automotive Atmel Corporation, AT90CAN32 Automotive Datasheet - Page 261

no-image

AT90CAN32 Automotive

Manufacturer Part Number
AT90CAN32 Automotive
Description
Manufacturer
Atmel Corporation

Specifications of AT90CAN32 Automotive

Flash (kbytes)
32 Kbytes
Pin Count
64
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
53
Ext Interrupts
8
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Can
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
2
Eeprom (bytes)
1024
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 125
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
4
Output Compare Channels
8
Input Capture Channels
2
Pwm Channels
7
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
19.11.2
7682C–AUTO–04/08
CAN MOb Control and DLC Register - CANCDMOB
• Bit 1 – FERR: Form Error
This flag can generate an interrupt. It must be cleared using a read-modify-write software routine
on the whole CANSTMOB register.
The form error results from one or more violations of the fixed form in the following bit fields:
• Bit 0 – AERR: Acknowledgment Error
This flag can generate an interrupt. It must be cleared using a read-modify-write software routine
on the whole CANSTMOB register.
No detection of the dominant bit in the acknowledge slot.
• Bit 7:6 – CONMOB1:0: Configuration of Message Object
These bits set the communication to be performed (no initial value after RESET).
These bits are not cleared once the communication is performed. The user must re-write the
configuration to enable a new communication.
• Bit 5 – RPLV: Reply Valid
Used in the automatic reply mode after receiving a remote frame.
• Bit 4 – IDE: Identifier Extension
IDE bit of the remote or data frame to send.
This bit is updated with the corresponding value of the remote or data frame received.
• Bit 3:0 – DLC3:0: Data Length Code
Number of Bytes in the data field of the message.
• CRC delimiter.
• Acknowledgment delimiter.
• EOF
• This operation is necessary to be able to reset the BXOK flag.
• This operation also set the corresponding bit in the CANEN registers.
Initial Value
Read/Write
Bit
– 00 - disable.
– 01 - enable transmission.
– 10 - enable reception.
– 11 - enable frame buffer reception
– 0 - reply not ready.
– 1 - reply ready and valid.
– 0 - CAN standard rev 2.0 A (identifiers length = 11 bits).
– 1 - CAN standard rev 2.0 B (identifiers length = 29 bits).
CONMOB1 CONMOB0
R/W
7
-
R/W
6
-
RPLV
R/W
5
-
R/W
IDE
4
-
DLC3
R/W
3
-
DLC2
R/W
2
-
AT90CAN32/64/128
DLC1
R/W
1
-
DLC0
R/W
0
-
CANCDMOB
261