cx28394 Conexant Systems, Inc., cx28394 Datasheet - Page 106

no-image

cx28394

Manufacturer Part Number
cx28394
Description
Quad/x16/octal-t1/e1/j1 Framers
Manufacturer
Conexant Systems, Inc.
Datasheet
2.0 Circuit Description
2.4 Transmitter
2-48
Yellow Alarm Generation
Yellow Alarm, also referred to as RAI (Remote Alarm Indication), is a bit pattern
inserted into the transmit stream to alert far-end equipment that the local receiver
cannot recover data. Yellow Alarm/RAI is typically transmitted during receive
loss of frame and is defined differently depending upon the transmit frame format
configured [TFRAME; addr 070].
transmitted for each frame format.
Table 2-6. Yellow Alarm Generation
Bit Name
INS_YEL
TYEL
AUTO_YEL
RLOF
RLOF_INTEG
INS_YEL. Yellow Alarm/RAI is inserted only when INS_YEL is set, otherwise
these bit positions are supplied by data from TPCMI. Yellow Alarm/RAI
generation can be done manually or automatically.
bit will immediately and unconditionally overwrite the Yellow Alarm/RAI signal
bit(s) in the transmitted data stream with the appropriate pattern.
RLOF, and RLOF_INTEG. If AUTO_YEL is set, Yellow Alarm/RAI is generated
during a receive loss of frame alignment (RLOF = 1). Optionally, RLOF
integration can be enabled by setting RLOF_INTEG. In this case, both RLOF
indication and Yellow Alarm/RAI generation are delayed for approximately 2.5
seconds if a continuous out-of-frame condition exists. Yellow Alarm/RAI
generation continues for at least 1 second after RLOF clears.
NOTE(S):
(1)
Transmission of Yellow Alarm/RAI is controlled by these register bits:
Insertion of Yellow Alarm/RAI into the transmit stream is controlled by
Manual generation of Yellow Alarm/RAI is controlled by TYEL. Setting this
Automatic generation of Yellow Alarm/RAI is controlled by AUTO_YEL,
Frame Format
Yellow Alarm/RAI for T1-ESF framing is defined as a BOP priority codeword in the FDL
channel. T1-ESF Yellow Alarm/RAI is not transmitted using the procedure described
below. Instead, T1- ESF Yellow Alarm/RAI is generated by configuring DL1 to
continuously transmit an all zeros BOP priority codeword. Refer to
Transmit Data
SF/JYEL
SLC-96
ESF
T1DM
SF
E1
(1)
Links.
Conexant
Bit 2 of every time slot set to zero
Bit 2 of every time slot set to zero
Bit 2 of every time slot set to zero
F-bit 12 of every superframe set to one
Y bit of the sync byte set to zero
The A bit of TS0 set to one
Register
TFRM; addr 072]
TALM; addr 075]
TALM; addr 075]
ALM1; addr 047]
RALM; addr 045]
Yellow Alarm Transmitted
Table 2-6
describes the Yellow Alarm/RAI
Quad/x16/Octal—T1/E1/J1 Framers
CX28394/28395/28398
Section 2.4.2,
100054E
Mode
YB2
YB2
YB2
Y24
YJ
Y0

Related parts for cx28394