cx28394 Conexant Systems, Inc., cx28394 Datasheet - Page 125

no-image

cx28394

Manufacturer Part Number
cx28394
Description
Quad/x16/octal-t1/e1/j1 Framers
Manufacturer
Conexant Systems, Inc.
Datasheet
CX28394/28395/28398
Quad/x16/Octal—T1/E1/J1 Framers
Table 3-4. Address Map (1 of 5)
100054E
Block
Address
(Hex)
000
080
081
082
083
001
003
004
005
006
007
008
009
00A
00B
00C
00D
00E
010
011
012
013
014
015
016
017
018
019
01A
020
021
00F
DID
FCR
MIR
MIE
TEST
CR0
IRR
ISR7
ISR6
ISR5
ISR4
ISR3
ISR2
ISR1
ISR0
IER7
IER6
IER5
IER4
IER3
IER2
IER1
IER0
LOOP
DL3_TS
DL3_BIT
FSTAT
PIO
POE
CMUX
RAC
RSTAT
Acronym
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
Device Identification
Framer Control Register
Master Interrupt Request
Master Interrupt Enable
Test Configuration
Primary Control Register
Interrupt Request Register
Alarm 1 Interrupt Status
Alarm 2 Interrupt Status
Error Interrupt Status
Counter Overflow Interrupt Status
Timer Interrupt Status
Data Link 1 Interrupt Status
Data Link 2 Interrupt Status
Pattern Interrupt Status
Alarm 1 Interrupt Enable Register
Alarm 2 Interrupt Enable Register
Error Interrupt Enable Register
Count Overflow Interrupt Enable Register
Timer Interrupt Enable Register
Data Link 1 Interrupt Enable Register
Data Link 2 Interrupt Enable Register
Pattern Interrupt Enable Register
Loopback Configuration Register
External Data Link Channel
External Data Link Bit
Offline Framer Status
Programmable Input/Output
Programmable Output Enable
Clock Input Mux
Receive Alarm Configuration
Receive Line Code Status
Conexant
Description
Setting (Hex)
3.1 Address Map
Register
3.0 Registers
Default
28
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
3C
00
3-3

Related parts for cx28394