DF2506BR26DV Renesas Electronics America, DF2506BR26DV Datasheet - Page 697

IC H8S/2506 MCU FLASH 176-LFBGA

DF2506BR26DV

Manufacturer Part Number
DF2506BR26DV
Description
IC H8S/2506 MCU FLASH 176-LFBGA
Manufacturer
Renesas Electronics America
Series
H8® H8S/2500r
Datasheets

Specifications of DF2506BR26DV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
26MHz
Connectivity
I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
104
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
176-LFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2506BR26DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
CPU Interrupt Source Settings: CPU interrupt source settings are made in the interrupt mask
register (IMR) and mailbox interrupt register (MBIMR). The message to be received is also
specified. Data frame and remote frame receive wait interrupt requests can be generated for
individual mailboxes in the MBIMR. Interrupt sources of the interrupt register (IRR) are enabled
by IMR.
Arbitration Field Setting: To receive a message, the message identifier must be set in advance in
the message control registers (MCx[1] to MCx[8]) for the receiving mailbox. When a message is
received, all the bits in the receive message identifier are compared with those in each message
control register identifier, and if a 100% match is found, the message is stored in the matching
mailbox. Mailbox 0 has a local acceptance filter mask (LAFM) that allows Don't Care settings to
be made. The LAFM setting can be made only for mailbox 0. By making the Don't Care setting
for all the bits in the receive message identifier, messages of multiple identifiers can be received.
Examples:
• When the identifier of mailbox 1 is 010_1010_1010 (standard format), only one kind of
• When the identifier of mailbox 0 is 010_1010_1010 (standard format) and the LAFM setting is
Message Reception: When a message is received, a CRC check is performed automatically. If the
result of the CRC check is normal, ACK is transmitted in the ACK field irrespective of whether
the message can be received or not.
• Data frame reception
message identifier can be received by mailbox 1:
Identifier 1:
000_0000_0011 (0: Care, 1: Don't Care), a total of four kinds of message identifiers can be
received by mailbox 0:
Identifier 1:
Identifier 2:
Identifier 3:
Identifier 4:
If the received message is confirmed to be error-free by the CRC check, the identifier in the
mailbox (and also LAFM in the case of mailbox 0 only) and the identifier of the receive
message, are compared. If a complete match is found, the message is stored in the mailbox.
The message identifier comparison is carried out on each mailbox in turn, starting with
mailbox 0 and ending with mailbox 15. If a complete match is found, the comparison ends at
that point, the message is stored in the matching mailbox, and the corresponding receive
complete bit (RXPR0 to RXPR15) is set in the receive complete register (RXPR). However,
when a mailbox 0 LAFM comparison is carried out, even if the identifier matches, the mailbox
010_1010_1010
010_1010_1000
010_1010_1001
010_1010_1010
010_1010_1011
Section 18 Controller Area Network (HCAN) [H8S/2556 Group]
Rev. 6.00 Sep. 24, 2009 Page 649 of 928
REJ09B0099-0600