UPD78F0550MA-FAA-AX Renesas Electronics America, UPD78F0550MA-FAA-AX Datasheet - Page 343

no-image

UPD78F0550MA-FAA-AX

Manufacturer Part Number
UPD78F0550MA-FAA-AX
Description
MCU 8BIT 16-SSOP
Manufacturer
Renesas Electronics America
Series
78K0/Kx2-Lr
Datasheet

Specifications of UPD78F0550MA-FAA-AX

Package / Case
*
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Speed
10MHz
Number Of I /o
12
Core Processor
78K/0
Program Memory Type
FLASH
Ram Size
384 x 8
Program Memory Size
4KB (4K x 8)
Data Converters
A/D 4x10b
Oscillator Type
Internal
Peripherals
LVD, POR, PWM, WDT
Connectivity
I²C, LIN, UART/USART
Core Size
8-Bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F0550MA-FAA-AX
Manufacturer:
Renesas
Quantity:
800
Part Number:
UPD78F0550MA-FAA-AX
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Address: FF9EH
(3) Real-time counter control register 1 (RTCC1)
RTCC1
Symbol
The RTCC1 register is an 8-bit register that is used to control the alarm interrupt function and the wait time of
the counter.
RTCC1 can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
To set the registers of alarm (WALIE flag of RTCC1, ALARMWM register, ALARMWH register, and ALARMWW
register), disable WALE (clear it to “0”).
This is a status flag that indicates detection of matching with the alarm. It is valid only when WALE = 1 and is set to
“1” one clock (32.768 kHz) after matching of the alarm is detected. This flag is cleared when “0” is written to it.
Writing “1” to it is invalid.
WALIE
WAFG
WALE
WALE
<7>
Figure 10-4. Format of Real-Time Counter Control Register 1 (RTCC1) (1/2)
After reset: 00H
0
1
0
1
0
1
Match operation is invalid.
Match operation is valid.
Does not generate interrupt on matching of alarm.
Generates interrupt on matching of alarm.
Alarm mismatch
Detection of matching of alarm
WALIE
<6>
R/W
CHAPTER 10 REAL-TIME COUNTER
Preliminary User’s Manual U19111EJ2V1UD
5
0
Control of alarm interrupt (INTRTC) function operation
WAFG
<4>
Alarm detection status flag
Alarm operation control
RIFG
<3>
2
0
RWST
<1>
RWAIT
<0>
343

Related parts for UPD78F0550MA-FAA-AX