R88M-WP20030H-BW Omron, R88M-WP20030H-BW Datasheet - Page 282

no-image

R88M-WP20030H-BW

Manufacturer Part Number
R88M-WP20030H-BW
Description
SERVO MOTOR 200W 200V W/BRAKE
Manufacturer
Omron
Datasheet

Specifications of R88M-WP20030H-BW

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP20030HBW
Operation
Note 1. Always set this parameter to 1 when using a DC power supply. If a DC power supply is con-
Note 2. If using a DC power supply, the regeneration absorption circuit inside the Servo Driver will not
Note 3. If using a DC power supply, the residual voltage in the main-circuit power supply is not dis-
Setting Explanation
• Select whether the alarm code output will be from outputs ALO1 to ALO3 (CN1-37 to 39) if an alarm
Note Refer to 5-2 Alarms for warning code details.
D Function Selection Application Switch 2 (Pn002: Default Setting 0000)
Setting Explanation
• Set TREF (torque command input) function when using position control and speed control.
4-44
Pn001.3
Setting
range
0
1
Pn002.0
Setting
range
0
1
2
3
(overload alarm, regeneration overload alarm) occurs.
Main circuit power supply: Supply DC power as follows: positive voltage to +1 terminal, and ground
to – terminal.
External regeneration resistance terminals: Remove the short bar from between B2 and B3 so that
B1, B2, and B3 are open. (For Servo Drivers without B3, open B1 and B2.)
Make sure input voltage is 120 to 179 V DC for 100 V input type, and 240 to 357 V DC for 200 V input
type.
Setting
Setting
nected with this parameter set to 0, the regeneration absorption circuit will operate, possibly
damaging the Servo Driver. When changing the setting from 0 to 1, either the main circuit pow-
er supply must be OFF, or the external regeneration resistance terminals must be open.
operate. The regeneration power returns to the DC power supply, so make sure the DC power
supply can absorb the regeneration power.
charged rapidly when the power is turned OFF. Be sure to mount a discharge circuit on the DC
power supply. Also, check that the charge indicator is not lit before storing the power supply
input when the power supply has been turned OFF (the discharge time for the Servo Driver is
approximately 30 minutes.)
Function selection application switch 1 –– Warning code output selection (All operation
modes)
0, 1
Function selection application switch 2 –– Torque command input change (Position, speed)
0 to 3
Only alarm code is output from ALO1, ALO2, and ALO3
Both alarm code and warning code are output from ALO1, ALO2, and ALO3
Function not used.
TREF used as analog torque limit.
TREF used as torque feed-forward input.
TREF used as analog torque limit when PCL and NCL are ON.
Unit
Unit
---
---
Default
setting
Default
setting
Explanation
Explanation
1
0
Restart
power?
Restart
power?
Chapter 4
Yes
Yes

Related parts for R88M-WP20030H-BW