(21) Operation when Error Occurs during Complementary PWM Mode Operation, and
Figure 12.147 shows an explanatory diagram of the case where an error occurs in complementary
PWM mode and operation is restarted in normal mode after re-setting.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. The count operation is stopped by TSTR. (MTU2 output becomes the complementary PWM
11. Set normal mode. (MTU2 output goes low.)
12. Initialize the pins with TIOR.
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
R01UH0026EJ0300 Rev. 3.00
Sep 24, 2010
MTU2
module output
TIOC3A
TIOC3B
TIOC3D
Port output
PB16
PB17
PB19
After a power-on reset, MTU2 output is low and ports are in the high-impedance state.
Select the complementary PWM output level and cyclic output enabling/disabling with
TOCR.
Set complementary PWM.
Enable channel 3 and 4 output with TOER.
Set MTU2 output with the PFC.
The count operation is started by TSTR.
The complementary PWM waveform is output on compare-match occurrence.
An error occurs.
Set port output with the PFC and output the inverse of the active level.
output initial value.)
Operation is Restarted in Normal Mode
Power-on
Figure 12.147 Error Occurrence in Complementary PWM Mode,
reset
1
TOCR
2
(CPWM)
TMDR
Hi-Z
Hi-Z
Hi-Z
3
TOER
(1)
4
Recovery in Normal Mode
(MTU2)
PFC
5
TSTR
(1)
6
Match
7
occurs
Error
8
Section 12 Multi-Function Timer Pulse Unit 2 (MTU2)
(PORT)
PFC
9
TSTR
(0)
10
(normal)
TMDR
11
0 out)
(1 init
TIOR
12
(MTU2)
PFC
13
Page 589 of 1190
TSTR
(1)
14