SC1200UFH-266 AMD (ADVANCED MICRO DEVICES), SC1200UFH-266 Datasheet - Page 360

no-image

SC1200UFH-266

Manufacturer Part Number
SC1200UFH-266
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of SC1200UFH-266

Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC1200UFH-266
Quantity:
12 388
Part Number:
SC1200UFH-266
Manufacturer:
AMD
Quantity:
748
Part Number:
SC1200UFH-266
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
SC1200UFH-266BF
Manufacturer:
TDK
Quantity:
120
Part Number:
SC1200UFH-266F
Manufacturer:
CONEXANT
Quantity:
230
Part Number:
SC1200UFH-266F 33
Manufacturer:
RENESAS
Quantity:
2 342
360
Offset 08h-0Bh
31:25
23:22
19:18
15:10
Bit
7:2
1:0
10
24
21
20
17
16
9
8
9
Description
Auto-Flip. Video port operation mode.
0: The video port automatically detects the even and odd fields based on the VP_HREF and VP_VSYNC_IN signals or the
1: The even/odd field detect logic is disabled and the video port automatically toggles between the even and odd buffers
This bit must be programmed to 0 when Direct Video mode is used. Direct Video mode is used when VID_SEL = 10
(F4BAR0+Memory Offset 400h[1:0]). Otherwise the video select from the GX1 module. VID_SEL indicates the source of the
video data.)
Capture (Store to Memory) VBI Data.
0: Disable.
1: Enable.
Capture (Store to Memory) Video Data.
0: Disable.
1: Enable.
Reserved. Must be set to 0.
Run Mode Capture. Selects capture run mode.
00: Stop capture at end of current line.
01: Stop capture at end of current field.
10 Reserved.
11: Start capture at beginning of next field.
Reserved.(Read Only)
Current Field. (Read Only)
0: Even field is being processed.
1: Odd field is being processed.
Reserved. (Read Only)
Base Register Not Updated. (Read Only) When set to 1, this bit indicates that one of the base registers (at
F4BAR2+Memory Offset 20h, 24h, 40h, and 44h) has been written but has not yet been updated.
0: All base registers are updated.
1: One or more of the base registers has not been updated.
FIFO Overflow Status Indication.
0: No overflow occurred.
1: An overflow occurred for the FIFO between the VIP and the Fast X-Bus.
Writing a 1 to this bit clears the status.
Reserved. (Read Only)
Line Interrupt (INTC#) Pending Status.
0: Interrupt not pending.
1: Interrupt pending.
Writing a 1 to this bit clears the status.
Field Interrupt (INTC) Pending Status.
0: Interrupt not pending.
1: Interrupt pending.
Writing a 1 to this bit clears the status.
Reserved. (Read Only)
VBI Data Capture Active. (Read Only)
0: VBI data is not being stored to memory.
1: VBI data is now being stored to memory.
Table 7-10. F4BAR2+Memory Offset: VIP Configuration Registers (Continued)
CCIR-656 control codes.
during capture. The odd buffer is the first to be filled in this mode.
32579B
Video Interface Status Register (R/W)
Video Processor Module - Video Processor Registers - Function 4
AMD Geode™ SC1200/SC1201 Processor Data Book
Reset Value: xxxxxxxxh